  1. 原著論文

Final tests of the four switching network units procured by the European Union for JT-60SA

https://repo.qst.go.jp/records/48927
https://repo.qst.go.jp/records/48927
1714b454-efeb-46f8-97f4-103be4d66bdd
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-04-09
タイトル
タイトル Final tests of the four switching network units procured by the European Union for JT-60SA
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Lampasi, Alessandro.

× Lampasi, Alessandro.

WEKO 798162

Lampasi, Alessandro.

Search repository
Zito, Pietro

× Zito, Pietro

WEKO 798163

Zito, Pietro

Search repository
Novello, Luca

× Novello, Luca

WEKO 798164

Novello, Luca

Search repository
Matsukawa, Makoto

× Matsukawa, Makoto

WEKO 798165

Matsukawa, Makoto

Search repository
島田, 勝弘

× 島田, 勝弘

WEKO 798166

島田, 勝弘

Search repository
Burini, Filippo

× Burini, Filippo

WEKO 798167

Burini, Filippo

Search repository
Taddia, Giuseppe

× Taddia, Giuseppe

WEKO 798168

Taddia, Giuseppe

Search repository
Tenconi, Sandro

× Tenconi, Sandro

WEKO 798169

Tenconi, Sandro

Search repository
Matsukawa, Makoto

× Matsukawa, Makoto

WEKO 798170

en Matsukawa, Makoto

Search repository
Shimada, Katsuhiro

× Shimada, Katsuhiro

WEKO 798171

en Shimada, Katsuhiro

Search repository
抄録
内容記述タイプ Abstract
内容記述 Switching Network Units (SNUs) are inserted in the power supply circuits of modern tokamaks for plasma initiation. In the framework of the “Broader Approach” agreement, the four SNUs for the superconducting modules of the JT-60SA Central Solenoid will be procured by European Union through the Italian Agency ENEA.The design is based on the synchronized operations of a light electromechanical contactor and of a static switch to combine the benefits of both devices. The adopted solutions could be extended to many fusion and industrial applications. A SNU was able to divert to a breakdown resistance (from 0.25 Ω to 3.75 Ω) currents up to 20 kA, producing a voltage drop up to 5 kV in less than 100 µs with a transient overvoltage limited to about 200 V.The tests showed good performance repeatability for all the SNUs. The accuracy of all the breakdown resistors was well within ±2%. Specific tests showed that they could dissipate much more than 360 MJ.
書誌情報 Fusion Engineering and Design, Proceedings of the 29th Symposium on Fusion Technology (SOFT-29)

巻 124, p. 163-168, 発行日 2017-11
DOI
識別子タイプ DOI
関連識別子 10.1016/j.fusengdes.2017.02.010
関連サイト
識別子タイプ URI
関連識別子 https://www.sciencedirect.com/science/article/pii/S0920379617300935
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:39:01.816287
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3