ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Analysis of Quench Propagation in the ITER Central Solenoid Insert (CSI) Coil

https://repo.qst.go.jp/records/48908
https://repo.qst.go.jp/records/48908
02648061-93d9-4d3e-aea4-f3254d758093
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-05-08
タイトル
タイトル Analysis of Quench Propagation in the ITER Central Solenoid Insert (CSI) Coil
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Bonifetto, Roberto

× Bonifetto, Roberto

WEKO 492726

Bonifetto, Roberto

Search repository
Isono, Takaaki

× Isono, Takaaki

WEKO 492727

Isono, Takaaki

Search repository
Martovetsky, Nicolai

× Martovetsky, Nicolai

WEKO 492728

Martovetsky, Nicolai

Search repository
Savoldi, Laura

× Savoldi, Laura

WEKO 492729

Savoldi, Laura

Search repository
IEEE, Member

× IEEE, Member

WEKO 492730

IEEE, Member

Search repository
Zanino, Roberto

× Zanino, Roberto

WEKO 492731

Zanino, Roberto

Search repository
Member, IEEE Senior

× Member, IEEE Senior

WEKO 492732

Member, IEEE Senior

Search repository
礒野 高明

× 礒野 高明

WEKO 492733

en 礒野 高明

Search repository
抄録
内容記述タイプ Abstract
内容記述 The ITER Central Solenoid Insert (CSI) coil, a single-layer Nb3Sn solenoid, wound using the same conductor of the 3L module of the ITER Central Solenoid, was tested in 2015 at the National Institutes for Quantum and Radiological Science and Technology (Former JAEA) Naka, Japan, inside the bore of the Central Solenoid Model Coil. At the end of the test campaign, quench tests were carried out to study the quench initiation and propagation. Different delay time (up to 7 s) between quench detection and current dump were set, in order to explore to which extent the dump could be delayed without exceeding the maximum allowed hot spot temperature. The experimental data for different time delays are presented and compared, showing a good reproducibility of the measurements and confirming the safe operation of the coil during these tests. The previously developed and already extensively validated 4C thermal-hydraulic code is then used to model the tranient up to the current dump and a comprehensive comparison between the simulation results and the measurements is presented.
書誌情報 IEEE Transaction on Applied Superconductivity

巻 27, 号 4, p. 4700308, 発行日 2018-05
ISSN
収録物識別子タイプ ISSN
収録物識別子 1051-8223
DOI
識別子タイプ DOI
関連識別子 10.1109/TASC.2016.2634598
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:23:00.341621
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3