  1. 原著論文

Measurement of transient flow characteristics of target flow in water experiment for IFMIF

https://repo.qst.go.jp/records/48899
https://repo.qst.go.jp/records/48899
a3eee39a-d788-42fa-907e-bf7aed6291e7
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-05-08
タイトル
タイトル Measurement of transient flow characteristics of target flow in water experiment for IFMIF
言語
言語 jpn
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Matsuda, Shotaro

× Matsuda, Shotaro

WEKO 492631

Matsuda, Shotaro

Search repository
Kanemura, Takuji

× Kanemura, Takuji

WEKO 492632

Kanemura, Takuji

Search repository
近藤, 浩夫

× 近藤, 浩夫

WEKO 492633

近藤, 浩夫

Search repository
Kaji, Sayaka

× Kaji, Sayaka

WEKO 492634

Kaji, Sayaka

Search repository
Okita, Tkafumi

× Okita, Tkafumi

WEKO 492635

Okita, Tkafumi

Search repository
Yoshihashi, Sachiko

× Yoshihashi, Sachiko

WEKO 492636

Yoshihashi, Sachiko

Search repository
Hoashi, Eiji

× Hoashi, Eiji

WEKO 492637

Hoashi, Eiji

Search repository
Horiike, Hiroshi

× Horiike, Hiroshi

WEKO 492638

Horiike, Hiroshi

Search repository
近藤 浩夫

× 近藤 浩夫

WEKO 492639

en 近藤 浩夫

Search repository
抄録
内容記述タイプ Abstract
内容記述 International Fusion Material Irradiation Facility (IFMIF) is the facility generating the high flux and high energy neutrons to develop fusion reactor materials. In IFMIF, high-speed liquid lithium (Li) jet is used as the target irradiated by deuteron beams. Since the Li jet must flow with high velocity for heat removal, it is important to research on the Li flow characteristics. These researches have been aimed toward the steady-state Li flow characteristics. On the other hand, in the actual IFMIF, it is also necessary to clarify transient flow characteristics at start and stop of the system for the operation. In this study, water experiment to obtain them at start and stop is thus conducted. Water can be substituted for liquid Li as the target, because the kinematic viscosity of the Li at operation temperature in IFMIF is nearly equal to that of water at normal temperature and pressure. Flow patterns of the water jet at test section which consists of a two-staged contraction nozzle, a vertical concave flow channel are observed by laser probe method and high-speed video camera. As a result, the flow pattern at start and stop was successfully observed. The flow at stop became stable by venting gas.
書誌情報 Fusion Engineering and Design

巻 124, p. 1096-1100, 発行日 2018-05
DOI
識別子タイプ DOI
関連識別子 10.1016/j.fusengdes.2017.03.111
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:23:06.265270
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3