Radiological consequences of a bounding event sequence of Advanced Fusion Neutron Source (A-FNS)

https://repo.qst.go.jp/records/48847
https://repo.qst.go.jp/records/48847
56bafe45-0a03-4647-895e-c99598a3fc6c
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-05-08
タイトル
タイトル Radiological consequences of a bounding event sequence of Advanced Fusion Neutron Source (A-FNS)
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 中村, 誠

× 中村, 誠

WEKO 492027

中村, 誠

Search repository
落合, 謙太郎

× 落合, 謙太郎

WEKO 492028

落合, 謙太郎

Search repository
中村 誠

× 中村 誠

WEKO 492029

en 中村 誠

Search repository
落合 謙太郎

× 落合 謙太郎

WEKO 492030

en 落合 謙太郎

Search repository
抄録
内容記述タイプ Abstract
内容記述 Advanced Fusion Neutron Source (A-FNS) is an accelerator-based neutron source utilizing Li(d,xn) nuclear stripping reactions to simulate D-T fusion neutrons for testing and qualifying structural and functional materials of fusion reactor components, which is to be constructed at the Rokkasho site of National Institutes for Quantum and Radiological Science and Technology, Japan, in the near future. The purpose of the study reported here is to demonstrate the ultimate safety margins of A-FNS in the worst case of release of radioactive materials outside the A-FNS confinement system. For this purpose, we analyzed a ‘bounding event’ postulated in A-FNS. The postulated event sequence consists of fire of the purification system of the liquid Li loop during the maintenance, of mobilization of the tritium and 7Be, which are the impurities of the loop, and of the entire loss of confinement of the radioactive materials. We have calculated the early doses to the public due to the release of the tritium and 7Be source terms to the environment. The UFOTRI/COSYMA simulations have been performed considering the site boundary of 500 m away from the facility. The obtained results indicate that the early dose is below the level that requires the emergent public evacuation. Such results demonstrate that the A-FNS complies with the defined safety objective against its radiation hazard. The simulation results suggest that the inherent, ultimate safety characteristic found by this study may assist a licensing process for installation of A-FNS.
書誌情報 Fusion Engineering and Design

巻 118, p. 104-110, 発行日 2018-05
出版者
出版者 Elsevier
ISSN
収録物識別子タイプ ISSN
収録物識別子 0920-3796
DOI
識別子タイプ DOI
関連識別子 10.1016/j.fusengdes.2017.03.060
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:23:41.662333
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3