  1. 原著論文

Total reflection X-ray spectroscopy as a rapid analytical method for uranium determination in drainage water

https://repo.qst.go.jp/records/48837
https://repo.qst.go.jp/records/48837
e35845d1-b451-4416-a5a3-58f078f69f85
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-03-15
タイトル
タイトル Total reflection X-ray spectroscopy as a rapid analytical method for uranium determination in drainage water
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Matsuyama, Tsugufumi

× Matsuyama, Tsugufumi

WEKO 772633

Matsuyama, Tsugufumi

Search repository
Izumoto, Yukie

× Izumoto, Yukie

WEKO 772634

Izumoto, Yukie

Search repository
Imaseki, Hitoshi

× Imaseki, Hitoshi

WEKO 772635

Imaseki, Hitoshi

Search repository
Hamano, Tsuyoshi

× Hamano, Tsuyoshi

WEKO 772636

Hamano, Tsuyoshi

Search repository
Sakai, Yasuhiro

× Sakai, Yasuhiro

WEKO 772637

Sakai, Yasuhiro

Search repository
Yoshii, Hiroshi

× Yoshii, Hiroshi

WEKO 772638

Yoshii, Hiroshi

Search repository
Matsuyama, Tsugufumi

× Matsuyama, Tsugufumi

WEKO 772639

en Matsuyama, Tsugufumi

Search repository
Izumoto, Yukie

× Izumoto, Yukie

WEKO 772640

en Izumoto, Yukie

Search repository
Imaseki, Hitoshi

× Imaseki, Hitoshi

WEKO 772641

en Imaseki, Hitoshi

Search repository
Hamano, Tsuyoshi

× Hamano, Tsuyoshi

WEKO 772642

en Hamano, Tsuyoshi

Search repository
Yoshii, Hiroshi

× Yoshii, Hiroshi

WEKO 772643

en Yoshii, Hiroshi

Search repository
抄録
内容記述タイプ Abstract
内容記述 Uranium concentrations in drainage water are typically determined by α-spectrometry. However,due to the low specific radioactivity of uranium, the evaporation of large volumes of drainage water, followed by several hours of measurements, is required. Thus, the development of a rapid and simple detection method for uranium in drainage water would enhance the operation efficiency of radiation controlworkers.We herein propose a novel methodology based on total reflection X-ray fluorescence (TXRF) for the measurement of uranium in contaminated water. TXRF isa particularly desirable method for the rapid and simple evaluation of uranium in contaminated water, as chemical pretreatment of the sample solution is not necessary, measurement times are typically several seconds, and the required sample volume is low. We herein employed sample solutions containing several different concentrations of uranyl acetate with yttrium as an internal standard. The solutions were placed onto sample holders, and were dried prior to TXRFmeasurements. The relative intensity, otherwise defined as the net intensity ratio of the Lα peak of uranium to the Kα peak of yttrium, was directly proportional to the uranium concentration.Using this method, a TXRF detection limit for uranium in contaminated water of 0.30 μg/g was achieved.
書誌情報 JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY

巻 54, 号 9, p. 940-943, 発行日 2017-03
ISSN
収録物識別子タイプ ISSN
収録物識別子 0022-3131
DOI
識別子タイプ DOI
関連識別子 10.1080/00223131.2017.1331764
関連サイト
識別子タイプ URI
関連識別子 https://www.tandfonline.com/doi/full/10.1080/00223131.2017.1331764
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:48:49.242482
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3