Adaptation of stochastic microdosimetric kinetic model for charged-particle therapy treatment planning
https://repo.qst.go.jp/records/48835
https://repo.qst.go.jp/records/48835d5be88d7-bc99-4e0e-8db8-2053220719a7
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-05-07 | |||||
タイトル | ||||||
タイトル | Adaptation of stochastic microdosimetric kinetic model for charged-particle therapy treatment planning | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Inaniwa, T
× Inaniwa, T× Kanematsu, N× Inaniwa, Taku× Kanematsu, Nobuyuki |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The microdosimetric kinetic (MK) model underestimates the cell-survival fractions for high linear energy transfer (LET) and high dose irradiations. To address the issue, some researchers previously extended the MK model to the stochastic microdosimetric kinetic (SMK) model. In the SMK model, the radiation induced cell-survival fractions were estimated from the specific energies zd and zn absorbed by a microscopic subnuclear structure domain and a cell nucleus, respectively. By taking the stochastic nature of zn as well as that of zd into account, the SMK model could reproduce the measured cell-survival fractions for radiations with wide LET and dose ranges. However, treatment planning based on the SMK model was unrealistic in clinical practice due to its long computation time and huge memory space required for the computation. In this study, we modified the SMK model to shorten the computation time and to reduce the memory space required for the computation. By using the dose-averaged cell-nucleus specific energy per event in the SMK formalism, the stochastic nature of zn was reflected onto the estimated cell-survival fractions. The accuracy of the modified SMK model was examined through the comparison between the estimated and the measured survival fractions of human salivary gland tumor (HSG) cells and V79 cells. We then implemented the modified SMK model into the in-house treatment planning software for scanned charged-particle therapy to validate its applicability in clinical practice. As examples, treatment plans of helium-, carbon-, and neon-ion beams were made for an orbital tumor case. The modified SMK model could reproduce the measured cell-survival fractions more accurately comparing to the MK model especially for high-LET and high-dose irradiations. In summary, the modified SMK model offers the accuracy and simplicity required in treatment planning of scanned charged-particle therapy for wide LET and dose ranges. | |||||
書誌情報 |
Physics in Medicine & Biology 巻 63, 号 9, p. 095011, 発行日 2018-05 |
|||||
出版者 | ||||||
出版者 | IOP Publishing | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0031-9155 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1088/1361-6560/aabede | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://iopscience.iop.org/article/10.1088/1361-6560/aabede/pdf |