Correction of quenching effect of a small size OSL dosimeter using Eu:BaFBr and Ce:CaF2

https://repo.qst.go.jp/records/48800
https://repo.qst.go.jp/records/48800
51606a2a-b84e-4560-aaa4-f23a88a96a78
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-04-24
タイトル
タイトル Correction of quenching effect of a small size OSL dosimeter using Eu:BaFBr and Ce:CaF2
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Hirata, Yuho

× Hirata, Yuho

WEKO 491458

Hirata, Yuho

Search repository
Watanabe, Kenichi

× Watanabe, Kenichi

WEKO 491459

Watanabe, Kenichi

Search repository
Uritani, Akira

× Uritani, Akira

WEKO 491460

Uritani, Akira

Search repository
Yamazaki, Atsushi

× Yamazaki, Atsushi

WEKO 491461

Yamazaki, Atsushi

Search repository
Koba, Yusuke

× Koba, Yusuke

WEKO 491462

Koba, Yusuke

Search repository
Matsufuji, Naruhiro

× Matsufuji, Naruhiro

WEKO 491463

Matsufuji, Naruhiro

Search repository
Yanagida, Takayuki

× Yanagida, Takayuki

WEKO 491464

Yanagida, Takayuki

Search repository
Fukuda, Kentaro

× Fukuda, Kentaro

WEKO 491465

Fukuda, Kentaro

Search repository
古場 裕介

× 古場 裕介

WEKO 491466

en 古場 裕介

Search repository
松藤 成弘

× 松藤 成弘

WEKO 491467

en 松藤 成弘

Search repository
抄録
内容記述タイプ Abstract
内容記述 To accurately estimate an actual dose during radiotherapy treatment, dosimeters are required to be inserted into the affected region in a patient's body. Therefore, we are developing a small size dosimeter consisting of optical fibers and optically stimulated luminescence (OSL) elements. We fabricated two types of small size dosimeters using Eu:BaFBr and Ce:CaF2. We measured the Bragg peak of high energy carbon ions in a water equivalent material. OSL materials showed the quenching effect when irradiated by high linear energy transfer (LET) particles. The sensitivity of Eu:BaFBr and Ce:CaF2 monotonically decreased with different coefficients. The ratio of the signal intensity of these two OSL materials can uniquely determine the sensitivity of each OSL material. We corrected the quenching effect of the OSL dosimeters in the spread out Bragg peak with this relationship.
書誌情報 Radiation Measurements

巻 106, p. 246-251, 発行日 2017-11
出版者
出版者 Elsevier
DOI
識別子タイプ DOI
関連識別子 10.1016/j.radmeas.2017.03.043
関連サイト
識別子タイプ URI
関連識別子 https://www.sciencedirect.com/science/article/pii/S1350448717302330
関連名称 https://www.sciencedirect.com/science/article/pii/S1350448717302330
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:24:11.513795
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3