  1. 原著論文

Nonvolatile nuclear spin memory enables sensorunlimited nanoscale spectroscopy of small spin clusters

https://repo.qst.go.jp/records/48721
https://repo.qst.go.jp/records/48721
e91707ed-eb56-44b4-98bc-cb8c9ab8bfd4
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-04-15
タイトル
タイトル Nonvolatile nuclear spin memory enables sensorunlimited nanoscale spectroscopy of small spin clusters
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Pfender, Matthias

× Pfender, Matthias

WEKO 490232

Pfender, Matthias

Search repository
Aslam, Nabeel

× Aslam, Nabeel

WEKO 490233

Aslam, Nabeel

Search repository
Sumiya, Hitoshi

× Sumiya, Hitoshi

WEKO 490234

Sumiya, Hitoshi

Search repository
Onoda, Shinobu

× Onoda, Shinobu

WEKO 490235

Onoda, Shinobu

Search repository
Neumann, Philipp

× Neumann, Philipp

WEKO 490236

Neumann, Philipp

Search repository
Isoya, Junichi

× Isoya, Junichi

WEKO 490237

Isoya, Junichi

Search repository
A., Meriles Carlos

× A., Meriles Carlos

WEKO 490238

A., Meriles Carlos

Search repository
Wrachtrup, Jörg

× Wrachtrup, Jörg

WEKO 490239

Wrachtrup, Jörg

Search repository
小野田 忍

× 小野田 忍

WEKO 490240

en 小野田 忍

Search repository
抄録
内容記述タイプ Abstract
内容記述 In nanoscale metrology, dissipation of the sensor limits its performance. Strong dissipation has a negative impact on sensitivity, and sensor–target interaction even causes relaxation or dephasing of the latter. The weak dissipation of nitrogen-vacancy (NV) sensors in room temperature diamond enables detection of individual target nuclear spins, yet limits the spectral resolution of nuclear magnetic resonance (NMR) spectroscopy to several hundred Hertz, which typically prevents molecular recognition. Here, we use the NV intrinsic nuclear spin as a nonvolatile classical memory to store NMR information, while suppressing sensor back-action on the target using controlled decoupling of sensor, memory, and target. We demonstrate memory lifetimes up to 4 min and apply measurement and decoupling protocols, which exploit such memories efficiently. Our universal NV-based sensor device records single-spin NMR spectra with 13 Hz resolution at room temperature.
書誌情報 Nature Communications

巻 8, 号 834, p. 1-12, 発行日 2017-10
出版者
出版者 Nature Pub. Group
DOI
識別子タイプ DOI
関連識別子 10.1038/s41467-017-00964-z
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:25:02.260568
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3