ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Optimum size of a calibration phantom for x-ray CT to convert the Hounsfield units to stopping power ratios in charged particle therapy treatment planning

https://repo.qst.go.jp/records/48684
https://repo.qst.go.jp/records/48684
1ccf7588-7eb3-4019-ba50-86e384b4fe38
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-04-08
タイトル
タイトル Optimum size of a calibration phantom for x-ray CT to convert the Hounsfield units to stopping power ratios in charged particle therapy treatment planning
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Inaniwa, T.

× Inaniwa, T.

WEKO 489823

Inaniwa, T.

Search repository
Tashima, H.

× Tashima, H.

WEKO 489824

Tashima, H.

Search repository
Kanematsu, N.

× Kanematsu, N.

WEKO 489825

Kanematsu, N.

Search repository
稲庭 拓

× 稲庭 拓

WEKO 489826

en 稲庭 拓

Search repository
田島 英朗

× 田島 英朗

WEKO 489827

en 田島 英朗

Search repository
兼松 伸幸

× 兼松 伸幸

WEKO 489828

en 兼松 伸幸

Search repository
抄録
内容記述タイプ Abstract
内容記述 In charged-particle therapy treatment planning, the volumetric distribution of stopping power ratios (SPRs) of body tissues relative to water is used for patient dose calculation. The distribution is conventionally obtained from computed tomography (CT) images of a patient using predetermined conversion functions from the CT numbers to the SPRs. One of the biggest uncertainty sources of patient SPR estimation is insufficient correction of beam hardening arising from the mismatch between the size of the patient cross section and the calibration phantom for producing the conversion functions. The uncertainty would be minimized by selecting a suitable size of the cylindrical water calibration phantom referred to as an “effective size” of the patient cross section, Leffective. We investigated the Leffective for pelvis, abdomen, thorax, and head and neck regions by simulating an ideal CT system using volumetric models of the reference male and female phantoms. The Leffective values were 23.3, 20.3, 22.7 and 18.8 cm for the pelvis, abdomen, thorax, and head and neck regions, respectively, and the Leffective for whole body was 21.0 cm. Using the conversion function for a 21.0-cm-diameter cylindrical water phantom, we could reduce the root mean square deviation of the SPRs and their mean deviation to ≤ 0.011 and ≤ 0.001, respectively, in the whole body. Accordingly, for simplicity, the effective size of 21.0 cm can be used for the whole body, irrespective of body-part regions for treatment planning in clinical practice.
書誌情報 Journal of Radiation Research

巻 59, 号 2, p. 216-224, 発行日 2017-11
ISSN
収録物識別子タイプ ISSN
収録物識別子 0449-3060
PubMed番号
識別子タイプ PMID
関連識別子 29095996
DOI
識別子タイプ DOI
関連識別子 10.1093/jrr/rrx059
関連サイト
識別子タイプ URI
関連識別子 https://academic.oup.com/jrr/article/doi/10.1093/jrr/rrx059/4582868?guestAccessKey=cc323aac-a569-4bfa-9058-7b3fd7b86b3b
関連名称 https://academic.oup.com/jrr/article/doi/10.1093/jrr/rrx059/4582868?guestAccessKey=cc323aac-a569-4bfa-9058-7b3fd7b86b3b
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:25:27.043576
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3