  1. 原著論文

Investigation of spatial resolution improvement by use of a mouth-insert detector in the helmet PET scanner

https://repo.qst.go.jp/records/48679
https://repo.qst.go.jp/records/48679
c251c4db-a9d9-4487-93c4-b91c6b2b7e78
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-04-08
タイトル
タイトル Investigation of spatial resolution improvement by use of a mouth-insert detector in the helmet PET scanner
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Ahmed, Abdella

× Ahmed, Abdella

WEKO 489758

Ahmed, Abdella

Search repository
Tashima, Hideaki

× Tashima, Hideaki

WEKO 489759

Tashima, Hideaki

Search repository
Yamaya, Taiga

× Yamaya, Taiga

WEKO 489760

Yamaya, Taiga

Search repository
Ahmed Abdella Mohammednur

× Ahmed Abdella Mohammednur

WEKO 489761

en Ahmed Abdella Mohammednur

Search repository
田島 英朗

× 田島 英朗

WEKO 489762

en 田島 英朗

Search repository
山谷 泰賀

× 山谷 泰賀

WEKO 489763

en 山谷 泰賀

Search repository
抄録
内容記述タイプ Abstract
内容記述 The dominant factor limiting the intrinsic spatial resolution of a positron emission tomography (PET) system is the size of the crystal elements in the detector. To increase sensitivity and achieve high spatial resolution, it is essential to use advanced depth-of-interaction (DOI) detectors and arrange them close to the subject. The DOI detectors help maintain high spatial resolution by mitigating the parallax error caused by the thickness of the scintillator near the peripheral regions of the field-of-view. As an optimal geometry for a brain PET scanner, with high sensitivity and spatial resolution, we proposed and developed the helmet–chin PET scanner using 54 four-layered DOI detectors consisting of a 16 × 16 × 4 array of GSOZ scintillator crystals with dimensions of 2.8 × 2.8 × 7.5 mm3. All the detectors used in the helmet–chin PET scanner had the same spatial resolution. In this study, we conducted a feasibility study of a new add-on detector arrangement for the helmet PET scanner by replacing the chin detector with a segmented crystal cube, having high spatial resolution in all directions, which can be placed inside the mouth. The crystal cube (which we have named the mouth-insert detector) has an array of 20 × 20 × 20 LYSO crystal segments with dimensions of 1 × 1 × 1 mm3. Thus, the scanner is formed by the combination of the helmet and mouth-insert detectors, and is referred to as the helmet–mouth-insert PET scanner. The results show that the helmet–mouth-insert PET scanner has comparable sensitivity and improved spatial resolution near the center of the hemisphere, compared to the helmet–chin PET scanner.
書誌情報 Radiological Physics and Technology

巻 11, 号 1, p. 7-12, 発行日 2017-10
出版者
出版者 Springer Singapore
ISSN
収録物識別子タイプ ISSN
収録物識別子 1865-0333
PubMed番号
識別子タイプ PMID
関連識別子 28986818
DOI
識別子タイプ DOI
関連識別子 10.1007/s12194-017-0425-2
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:25:30.689382
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3