ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Ion pinhole imaging diagnostics on fast ion source in femtosecond laser plasma of cluster targets

https://repo.qst.go.jp/records/48637
https://repo.qst.go.jp/records/48637
2a5980fa-5cca-488c-a1d3-27cd8994b877
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-03-26
タイトル
タイトル Ion pinhole imaging diagnostics on fast ion source in femtosecond laser plasma of cluster targets
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 MAKAROV, S.

× MAKAROV, S.

WEKO 489163

MAKAROV, S.

Search repository
PIKUZ, S.

× PIKUZ, S.

WEKO 489164

PIKUZ, S.

Search repository
FAENOV, A.

× FAENOV, A.

WEKO 489165

FAENOV, A.

Search repository
PIKUZ, T.

× PIKUZ, T.

WEKO 489166

PIKUZ, T.

Search repository
福田, 祐仁

× 福田, 祐仁

WEKO 489167

福田, 祐仁

Search repository
SKOBELEV, I.

× SKOBELEV, I.

WEKO 489168

SKOBELEV, I.

Search repository
ZHVANIYA, I.

× ZHVANIYA, I.

WEKO 489169

ZHVANIYA, I.

Search repository
VARZAR, S.

× VARZAR, S.

WEKO 489170

VARZAR, S.

Search repository
神門, 正城

× 神門, 正城

WEKO 489171

神門, 正城

Search repository
KODAMA, R.

× KODAMA, R.

WEKO 489172

KODAMA, R.

Search repository
福田 祐仁

× 福田 祐仁

WEKO 489173

en 福田 祐仁

Search repository
神門 正城

× 神門 正城

WEKO 489174

en 神門 正城

Search repository
抄録
内容記述タイプ Abstract
内容記述 The spatial configuration of the ion source generated under femtosecond laser interaction with clusters is investigated. While intense laser pulses (36 fs, 60 mJ, intensity of 4 × 10^17 W/cm^2) propagated in CO_2 cluster (~0.22 μm in diameter) media, the shape of the obtained plasma ion source was registered for the first time by means of pinhole imaging method. The remarkable decrease in fast ion yield in the vicinity of the assumed best laser focus near the gas cluster jet axis is observed. Such observed anisotropy of the ion source is suggested to originate from the influence of the laser prepulse destroying clusters in advance to the arrival of the main pulse. The assumption is confirmed by optical shadowgraphy images of the plasma channel and is important for further development of an efficient laser-plasma- based fast ion source. Following the observed geometry of the ion source, the laser intensity limit allowing to accelerate ions to ~100 keV energy range was estimated.
書誌情報 Optics Express

巻 25, 号 14, p. 16419-16426, 発行日 2017-07
出版者
出版者 Optical Society of America
DOI
識別子タイプ DOI
関連識別子 10.1364/OE.25.016419
関連サイト
識別子タイプ DOI
関連識別子 https://doi.org/10.1364/OE.25.016419
関連名称 https://doi.org/10.1364/OE.25.016419
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:25:57.713100
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3