Intracellular Hypoxia of Tumor Tissue Estimated by Noninvasive Electron Paramagnetic Resonance Oximetry Technique Using Paramagnetic Probes
https://repo.qst.go.jp/records/48605
https://repo.qst.go.jp/records/486058d96b550-a526-4e4d-9dfa-e9998c01dbc1
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-03-22 | |||||
タイトル | ||||||
タイトル | Intracellular Hypoxia of Tumor Tissue Estimated by Noninvasive Electron Paramagnetic Resonance Oximetry Technique Using Paramagnetic Probes | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Matsumoto, Atsuko
× Matsumoto, Atsuko× Matsumoto, Ken-ichiro× Matsumoto, Shingo× Hyodo, Fuminori× L., Sowers Anastasia× W., Koscielniak Janusz× Devasahayam, Nallathamby× Subramanian, Sankaran× B., Mitchell James× C., Krishna Murali× 松本 厚子× 松本 謙一郎 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Electron paramagnetic resonance (EPR) oximetry at 700 MHz operating frequency employing a surface coil resonator is used to assess tissue partial pressure of oxygen (pO2) using paramagnetic media whose linewidth and decay constant are related to oxygen concentration. Differences in extracellular and intracellular pO2 in squamous cell carcinoma (SCC) tumor tissue were tested using several types of water-soluble paramagnetic media, which localize extracellularly or permeate through the cell membrane. The nitroxide carboxy-PROXYL (CxP) can only be distributed in blood plasma and extracellular fluids whereas the nitroxides carbamoyl-PROXYL (CmP) and TEMPOL (TPL) can permeate cell membranes and localize intracellularly. EPR signal decay constant and the linewidth of the intravenously administered nitroxides in SCC tumor tissues implanted in mouse thigh and the contralateral normal muscle of healthy mice breathing gases with different pO2 were compared. The pO2 in the blood can depend on the oxygen content in the breathing gas while tissue pO2 was not directly influenced by pO2 in the breathing gas. The decay constants of CmP and TPL in tumor tissue were significantly larger than in the normal muscles, and lower linewidths of CmP and TPL in tumor tissue was observed. The SCC tumor showed intracellular hypoxia even though the extracellular pO2 is similar to normal tissue in the peripheral region. | |||||
書誌情報 |
Biological & Pharmaceutical Bulletin 巻 34, 号 1, p. 142-145, 発行日 2010-10 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0918-6158 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1248/bpb.34.142 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.jstage.jst.go.jp/article/bpb/34/1/34_1_142/_article/-char/en | |||||
関連名称 | https://www.jstage.jst.go.jp/article/bpb/34/1/34_1_142/_article/-char/en |