  1. 原著論文

Mechanical property degradation of high crystalline SiC fiber–reinforced SiC matrix composite neutron irradiated to ∼100 displacements per atom

https://repo.qst.go.jp/records/48553
https://repo.qst.go.jp/records/48553
56f1a891-fc01-4a34-b717-43a35cf0bd0b
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-03-05
タイトル
タイトル Mechanical property degradation of high crystalline SiC fiber–reinforced SiC matrix composite neutron irradiated to ∼100 displacements per atom
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Koyanagi, Takaaki

× Koyanagi, Takaaki

WEKO 488193

Koyanagi, Takaaki

Search repository
Nozawa, Takashi

× Nozawa, Takashi

WEKO 488194

Nozawa, Takashi

Search repository
Katoh, Yutai

× Katoh, Yutai

WEKO 488195

Katoh, Yutai

Search repository
L., Snead Lance

× L., Snead Lance

WEKO 488196

L., Snead Lance

Search repository
野澤 貴史

× 野澤 貴史

WEKO 488197

en 野澤 貴史

Search repository
抄録
内容記述タイプ Abstract
内容記述 For the development of silicon carbide (SiC) materials for next-generation nuclear structural applications, degradation
of material properties under intense neutron irradiation is a critical feasibility issue. This study
evaluated the mechanical properties and microstructure of a chemical vapor infiltrated SiC matrix composite,
reinforced with a multi-layer SiC/pyrolytic carbon–coated Hi-NicalonTM Type S SiC fiber, following neutron
irradiation at 319 and 629 °C to ∼100 displacements per atom. Both the proportional limit stress and ultimate
flexural strength were significantly degraded as a result of irradiation at both temperatures. After irradiation at
319 °C, the quasi-ductile fracture behavior of the nonirradiated composite became brittle, a result that was
explained by a loss of functionality of the fiber/matrix interface associated with the disappearance of the interphase
due to irradiation. The specimens irradiated at 629 °C showed increased apparent failure strain because
the fiber/matrix interphase was weakened by irradiation-induced partial debonding.
書誌情報 Journal of the European Ceramic Society

巻 38, 号 4, p. 1087-1094, 発行日 2018-02
DOI
識別子タイプ DOI
関連識別子 10.1016/j.jeurceramsoc.2017.12.026
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:26:52.126254
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3