Development of a dual-ended readout detector with segmented crystal bars made using subsurface laser engraving technique

https://repo.qst.go.jp/records/48543
https://repo.qst.go.jp/records/48543
7ff375d5-24aa-4e25-919a-7605c566ac80
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-06-01
タイトル
タイトル Development of a dual-ended readout detector with segmented crystal bars made using subsurface laser engraving technique
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Mohammadi, Akram

× Mohammadi, Akram

WEKO 769207

Mohammadi, Akram

Search repository
Yoshida, Eiji

× Yoshida, Eiji

WEKO 769208

Yoshida, Eiji

Search repository
Nishikido, Fumihiko

× Nishikido, Fumihiko

WEKO 769209

Nishikido, Fumihiko

Search repository
Nitta, Munetaka

× Nitta, Munetaka

WEKO 769210

Nitta, Munetaka

Search repository
Shimizu, Kenji

× Shimizu, Kenji

WEKO 769211

Shimizu, Kenji

Search repository
Sakai, Toshiaki

× Sakai, Toshiaki

WEKO 769212

Sakai, Toshiaki

Search repository
Yamaya, Taiga

× Yamaya, Taiga

WEKO 769213

Yamaya, Taiga

Search repository
Mohammadi, Akram

× Mohammadi, Akram

WEKO 769214

en Mohammadi, Akram

Search repository
Yoshida, Eiji

× Yoshida, Eiji

WEKO 769215

en Yoshida, Eiji

Search repository
Nishikido, Fumihiko

× Nishikido, Fumihiko

WEKO 769216

en Nishikido, Fumihiko

Search repository
Nitta, Munetaka

× Nitta, Munetaka

WEKO 769217

en Nitta, Munetaka

Search repository
Yamaya, Taiga

× Yamaya, Taiga

WEKO 769218

en Yamaya, Taiga

Search repository
抄録
内容記述タイプ Abstract
内容記述 Depth of interaction (DOI) information is indispensable to improve sensitivity and spatial resolution of positron emission tomography (PET) systems especially for small field-of-view PET such as small animal PET and human brain PET. We have already developed a series of X’tal cube detectors for isotropic spatial resolution and we obtained the best isotropic resolution of 0.77 mm for the detectors with six-sided readout. However, it is still challenging to apply the detector for PET systems due to the high costs of six-sided readout electronics and carrying out segmentation of a monolithic cubic scintillator using the three-dimensional (3D) subsurface laser engraving (SSLE) technique. In this work, we proposed a more practical X’tal cube with the two-sided readout detector, which was made of crystal bars segmented by the one-dimensional (1D) SSLE technique. We developed two types of prototype detectors with a 3 mm cubic segment and a 1.5 mm cubic segment by using 3×3×20 mm3 and 1.5×1.5×20 mm3 crystal bars segmented into 7 and 13 DOI segments, respectively, using the 1D SSLE technique. First, performance of the detector composed of one crystal bar with different DOI segments and readout at both ends of two thorough silicon via (TSV) multi-pixel photon counters (MPPCs) were evaluated in order to demonstrate capability of the segmented crystal bars as a DOI detector. Then, performance evaluation was carried out for a 4×4 crystal array of 3×3×20 mm3 with 7 DOI segments and an 8×8 crystal array of 1.5×1.5×20 mm3 with 13 DOI segments. Each readout included a 4×4 channel of the 3×3 mm2 active area TSV MPPCs. The 3D position maps of the detectors were obtained by the Anger type calculation. All the segments in the 4×4 array were identified very clearly when there was air between the crystal bars as each crystal bar was coupled to one channel of the MPPCs; however, it was necessary to optimize optical conditions between crystal bars for the 8×8 array because of light sharing between crystal bars coupled to one channel of the MPPCs. The optimization was performed for the 8×8 array by inserting reflectors fully or partially between the crystal bars and the best crystal identification performance was obtained with the partial reflectors between the crystal bars. The mean energy resolutions at the 511 keV photo peak for the 4×4 array with air between the crystal bars and for the 8×8 array with partial reflectors between the crystal bars were 10.1% ± 0.3% and 10.8% ± 0.8%, respectively. Timing resolution of 783 ± 36 ps and 1.14 ± 0.22 ns were obtained for the detectors composed of the 4×4 array and the 8×8 array with partial reflectors, respectively. Practical X’tal cubes with 3 mm and 1.5 mm DOI resolutions and two-sided readout were developed.
書誌情報 Physics in Medicine & Biology

巻 63, 号 2, p. 025019-1-025019-11, 発行日 2017-12
出版者
出版者 IOP Publishing
ISSN
収録物識別子タイプ ISSN
収録物識別子 0031-9155
PubMed番号
識別子タイプ PMID
関連識別子 29176052
DOI
識別子タイプ DOI
関連識別子 10.1088/1361-6560/aa9d03
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:49:59.712678
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3