Development of bolometric tomography technique for high-contrast radiation distribution in toroidal devices

https://repo.qst.go.jp/records/48540
https://repo.qst.go.jp/records/48540
c2b69b21-1de7-40e7-8fe4-ad00b24a2698
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-02-22
タイトル
タイトル Development of bolometric tomography technique for high-contrast radiation distribution in toroidal devices
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 佐野, 竜一

× 佐野, 竜一

WEKO 487993

佐野, 竜一

Search repository
Peterson, Byron

× Peterson, Byron

WEKO 487994

Peterson, Byron

Search repository
向井清史

× 向井清史

WEKO 487995

向井清史

Search repository
福本, 正勝

× 福本, 正勝

WEKO 487996

福本, 正勝

Search repository
星野, 一生

× 星野, 一生

WEKO 487997

星野, 一生

Search repository
佐野 竜一

× 佐野 竜一

WEKO 487998

en 佐野 竜一

Search repository
福本 正勝

× 福本 正勝

WEKO 487999

en 福本 正勝

Search repository
星野 一生

× 星野 一生

WEKO 488000

en 星野 一生

Search repository
抄録
内容記述タイプ Abstract
内容記述 An extended Computed Tomography (CT) technique with a priori information based on Phillips-Tikhonov regularization has been developed to handle a high-contrast radiation distribution, which can result in large reconstruction errors in the region where radiation intensity is low, with few line of sight (LOS) data. Reference profiles generated from LOS data for every time slice are employed as the a priori information. In the extended technique, the weighting parameter for the reference profile is automatically determined from the LOS data, to avoid an inappropriate reference. The extended technique has been examined with a reconstruction test with the previously designed CT system using an infrared imaging video bolometer in JT-60SA. In the reconstructed profile of the high-contrast radiation distribution, the extended technique shows improvement of the weak radiation region, such as the scrape-off layer, without the deterioration of the strong radiation region, such as around the divertor. The results indicate that the extendedCTtechnique can help to handle a high-contrast radiation
distribution with few LOS data.
書誌情報 Review of Scientific instruments

巻 88, 号 9, p. 093504-1-093504, 発行日 2017-09
出版者
出版者 AIP Scitation
ISSN
収録物識別子タイプ ISSN
収録物識別子 0034-6748
DOI
識別子タイプ DOI
関連識別子 10.1063/1.5000951
関連サイト
識別子タイプ URI
関連識別子 http://aip.scitation.org/doi/full/10.1063/1.5000951
関連名称 http://aip.scitation.org/doi/full/10.1063/1.5000951
戻る
0
views
See details
Views