WEKO3
アイテム
Biological studies using mammalian cell lines and the current status of the microbeam irradiation system, SPICE
https://repo.qst.go.jp/records/48451
https://repo.qst.go.jp/records/48451e5f978c8-8daf-4c3b-bc2d-e26ba8de657c
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-02-04 | |||||
タイトル | ||||||
タイトル | Biological studies using mammalian cell lines and the current status of the microbeam irradiation system, SPICE | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Konishi, Teruaki
× Konishi, Teruaki× Iso, Hiroyuki× Ishikawa, Takahiro× Yasuda, Nakahiro× Oikawa, Masakazu× Kodama, Kumiko× Katou, Takeshi× Hafer, Kurt× Higuchi, Yuichi× Hamano, Tsuyoshi× Suya, Noriyoshi× Imaseki, Hitoshi× 小西 輝昭× 磯 浩之× 石川 剛弘× 安田 仲宏× 及川 将一× 児玉 久美子× 加藤 武伺× Hafer Kurt× 樋口 有一× 濱野 毅× 酢屋 徳啓× 今関 等 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A microbeam irradiation system, SPICE (Single Particle Irradiation system to Cell), is under completion at the National Institute of Radiological Sciences (NIRS). We have improved the beam size, which is now approximately 5 um in diameter, and the cell targeting system, which can irradiated a maximum of 400~500 cells per minute. Two types of cell dishes were specially designed. One is a Si3N4 plate (2.5 mmx2.5 mm area with 1 um thickness) supported by a 7.5 mmx7.5 mm frame of 200 um thickness, and the other is Mylar film stretched by pressing with a metal ring. These cell dishes can be placed on a voice coil stage equipped on the cell targeting system, which also includes of a fluorescent microscope and a CCD camera for capturing the cell images. This microscope system captures all the images of dyed cell nuclei, and computes the coordinates of the cell position according to the fluorescence, and synchronizes this and the voice coil motor stage with a single-particle irradiation system consisting of a scintillation counter and a beam deflector for irradiation. Irradiation of selected cells with a variable preset number of protons can be automatically performed. We employed the simultaneous detection method for visualizing the position of mammalian cells and proton traversal through CR-39 to determine whether the targeted cells are actually irradiated. An Immuno-assay was also performed against gamma-H2AX, to confirm the induction of DNA double-strand breaks in the target cells. | |||||
書誌情報 |
Nuclear Instruments & Methods in Physics Research Section B 巻 B267, 号 12/13, p. 2171-2175, 発行日 2009-03 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0168-583X | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.nimb.2009.03.060 |