ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Irradiation system of ions (H-Xe) for biological studies near the Bragg peak

https://repo.qst.go.jp/records/48448
https://repo.qst.go.jp/records/48448
815d0b8d-50f9-49bf-b785-c0f92436a720
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-02-04
タイトル
タイトル Irradiation system of ions (H-Xe) for biological studies near the Bragg peak
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Konishi, Teruaki

× Konishi, Teruaki

WEKO 487076

Konishi, Teruaki

Search repository
Takeyasu, Akihiro

× Takeyasu, Akihiro

WEKO 487077

Takeyasu, Akihiro

Search repository
Yasuda, Nakahiro

× Yasuda, Nakahiro

WEKO 487078

Yasuda, Nakahiro

Search repository
Ishizawa, Sachi

× Ishizawa, Sachi

WEKO 487079

Ishizawa, Sachi

Search repository
Nakajima, Hiroshi

× Nakajima, Hiroshi

WEKO 487080

Nakajima, Hiroshi

Search repository
Fujisaki, Takayuki

× Fujisaki, Takayuki

WEKO 487081

Fujisaki, Takayuki

Search repository
Furusawa, Yoshiya

× Furusawa, Yoshiya

WEKO 487082

Furusawa, Yoshiya

Search repository
Satou, Yukio

× Satou, Yukio

WEKO 487083

Satou, Yukio

Search repository
Hieda, Kotaro

× Hieda, Kotaro

WEKO 487084

Hieda, Kotaro

Search repository
小西 輝昭

× 小西 輝昭

WEKO 487085

en 小西 輝昭

Search repository
竹安 明弘

× 竹安 明弘

WEKO 487086

en 竹安 明弘

Search repository
安田 仲宏

× 安田 仲宏

WEKO 487087

en 安田 仲宏

Search repository
石澤 紗智

× 石澤 紗智

WEKO 487088

en 石澤 紗智

Search repository
中島 宏

× 中島 宏

WEKO 487089

en 中島 宏

Search repository
古澤 佳也

× 古澤 佳也

WEKO 487090

en 古澤 佳也

Search repository
佐藤 幸夫

× 佐藤 幸夫

WEKO 487091

en 佐藤 幸夫

Search repository
檜枝 光太郎

× 檜枝 光太郎

WEKO 487092

en 檜枝 光太郎

Search repository
抄録
内容記述タイプ Abstract
内容記述 We have developed a new system for irradiating biological samples in air with ions from H to Xe below 6.0MeV∕nucleon near the Bragg peak. The irradiation system can provide ion beams with 20‐mm diameter of which the central area of 100mm2 is uniform in fluence rate within a standard deviation of ±10%. For each ion, the linear energy transfer is selectable by irradiation positions in air, from the lowest at the surface of a vacuum window to the highest at the Bragg peak, for example, from 281 to 977 keV/μm for C ions. A wide range of fluence rates, 10−3–104ions∕μm2∕s, can be provided by the system, which makes it possible to irradiate a variety of biological samples with different target sizes, from small plasmid DNA to living mammalian cells. The ion fluence irradiated to each sample is calculated from the output of the secondary electron monitor using the linear relationship between the output and ion fluence measured at the sample position by CR-39 track detectors. Survival curves and visualization of NBS1 foci for human cells are presented as examples of preliminary experiments using C ions near the Bragg peak.
書誌情報 Review of Scientific Instruments

巻 76, 号 114302, p. 1-6, 発行日 2005-11
ISSN
収録物識別子タイプ ISSN
収録物識別子 0034-6748
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:27:59.032109
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3