ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Digital reconstructed radiography with multiple color image overlay for image-guided radiotherapy.

https://repo.qst.go.jp/records/48427
https://repo.qst.go.jp/records/48427
0e3d9feb-a6db-4136-8dbf-eaed3eedd228
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-01-11
タイトル
タイトル Digital reconstructed radiography with multiple color image overlay for image-guided radiotherapy.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yoshino, Shinichi

× Yoshino, Shinichi

WEKO 486790

Yoshino, Shinichi

Search repository
Miki, Kentaro

× Miki, Kentaro

WEKO 486791

Miki, Kentaro

Search repository
Sakata, Kozo

× Sakata, Kozo

WEKO 486792

Sakata, Kozo

Search repository
Nakayama, Yuko

× Nakayama, Yuko

WEKO 486793

Nakayama, Yuko

Search repository
Shibayama, Kouichi

× Shibayama, Kouichi

WEKO 486794

Shibayama, Kouichi

Search repository
Mori, Shinichiro

× Mori, Shinichiro

WEKO 486795

Mori, Shinichiro

Search repository
吉野 慎一

× 吉野 慎一

WEKO 486796

en 吉野 慎一

Search repository
三木 健太朗

× 三木 健太朗

WEKO 486797

en 三木 健太朗

Search repository
中山 優子

× 中山 優子

WEKO 486798

en 中山 優子

Search repository
柴山 晃一

× 柴山 晃一

WEKO 486799

en 柴山 晃一

Search repository
森 慎一郎

× 森 慎一郎

WEKO 486800

en 森 慎一郎

Search repository
抄録
内容記述タイプ Abstract
内容記述 Registration of patient anatomical structures to the reference position is a basic part of the patient set-up procedure. Registration of anatomical structures between the site of beam entrance on the patient surface and the distal target position is particularly important. Here, to improve patient positional accuracy during set-up for particle beam treatment, we propose a new visualization methodology using digitally reconstructed radiographs (DRRs), overlaid DRRs, and evaluation of overlaid DRR images in clinical cases. The overlaid method overlays two DRR images in different colors by dividing the CT image into two CT sections at the distal edge of the target along the treatment beam direction. Since our hospital uses fixed beam ports, the treatment beam angles for this study were set at 0 and 90 degrees. The DRR calculation direction was from the X-ray tube to the imaging device, and set to 180/270 degrees and 135/225 degrees, based on the installation of our X-ray imaging system. Original and overlaid DRRs were calculated using CT data for two patients, one with a parotid gland tumor and the other with prostate cancer. The original and overlaid DRR images were compared. Since the overlaid DRR image was completely separated into two regions when the DRR calculation angle was the same as the treatment beam angle, the overlaid DRR visualization technique was able to provide rich information for aiding recognition of the relationship between anatomical structures and the target position. This method will also be useful in patient set-up procedures for fixed irradiation ports.
書誌情報 Journal of radiation research

巻 56, 号 3, p. 588-593, 発行日 2015-05
出版者
出版者 Oxford University Press
ISSN
収録物識別子タイプ ISSN
収録物識別子 0449-3060
PubMed番号
識別子タイプ PMID
関連識別子 25678537
DOI
識別子タイプ DOI
関連識別子 10.1093/jrr/rrv002
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:28:13.830633
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3