ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

MRI compatibility study of an integrated PET/RF-coil prototype system at 3 T

https://repo.qst.go.jp/records/48354
https://repo.qst.go.jp/records/48354
9f531232-72fa-41a7-941d-a85c9ba678ab
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-11-02
タイトル
タイトル MRI compatibility study of an integrated PET/RF-coil prototype system at 3 T
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Md, Shahadat Hossain Akram

× Md, Shahadat Hossain Akram

WEKO 485948

Md, Shahadat Hossain Akram

Search repository
Obata, Takayuki

× Obata, Takayuki

WEKO 485949

Obata, Takayuki

Search repository
Suga, Mikio

× Suga, Mikio

WEKO 485950

Suga, Mikio

Search repository
Nishikido, Fumihiko

× Nishikido, Fumihiko

WEKO 485951

Nishikido, Fumihiko

Search repository
Yoshida, Eiji

× Yoshida, Eiji

WEKO 485952

Yoshida, Eiji

Search repository
Saito, Kazuyuki

× Saito, Kazuyuki

WEKO 485953

Saito, Kazuyuki

Search repository
Yamaya, Taiga

× Yamaya, Taiga

WEKO 485954

Yamaya, Taiga

Search repository
Md Shahadat Hossain Akram

× Md Shahadat Hossain Akram

WEKO 485955

en Md Shahadat Hossain Akram

Search repository
小畠 隆行

× 小畠 隆行

WEKO 485956

en 小畠 隆行

Search repository
菅 幹生

× 菅 幹生

WEKO 485957

en 菅 幹生

Search repository
錦戸 文彦

× 錦戸 文彦

WEKO 485958

en 錦戸 文彦

Search repository
吉田 英治

× 吉田 英治

WEKO 485959

en 吉田 英治

Search repository
山谷 泰賀

× 山谷 泰賀

WEKO 485960

en 山谷 泰賀

Search repository
抄録
内容記述タイプ Abstract
内容記述 We have been working on the development of a PET insert for existing magnetic resonance imaging (MRI) systems for simultaneous PET/MR imaging, which integrates radiofrequency (RF)-shielded PET detector modules with an RF head coil. In order to avoid interferences between the PET detector circuits and the different MRI-generated electromagnetic fields, PET detector circuits were installed inside eight Cu-shielded fiber-reinforced plastic boxes, and these eight shielded PET modules were integrated in between the eight elements of a 270-mm-diameter and 280-mm-axial-length cylindrical birdcage RF coil, which was designed to be used with a 3-T clinical MRI system. The diameter of the PET scintillators with a 12-mm axial field-of-view became 255 mm, which was very close to the imaging region. In this study, we have investigated the effects of this PET/RF-coil integrated system on the performance of MRI, which include the evaluation of static field (Bo) inhomogeneity, RF field (B1) distribution, local specific absorption rate (SAR) distribution, average SAR, and signal-to-noise ratio (SNR). For the central 170-mm-diameter and 80-mm-axial-length of a homogenous cylindrical phantom (with the total diameter of 200 mm and axial-length of 100 mm), an increase of about a maximum of 3 mT in the Bo inhomogeneity was found, both in the central and 40-mm off-centered transverse planes, and a 5 percentage point increase of B1 field inhomogeneity was observed in the central transverse plane (from 84% without PET to 79% with PET), while B1 homogeneity along the coronal plane was almost unchanged (77%) following the integration of PET with the RF head coil. The average SAR and maximum local SAR were increased by 1.21 and 1.62 times, respectively. However, the SNR study for both spin-echo and gradient-echo sequences showed a reduction of about 70% and 60%, respectively, because of the shielded PET modules. The overall results prove the feasibility of this integrated PET/RF-coil system for using with the existing MRI system.
書誌情報 Journal of Magnetic Resonance

巻 283, p. 62-70, 発行日 2017-08
ISSN
収録物識別子タイプ ISSN
収録物識別子 1090-7807
DOI
識別子タイプ DOI
関連識別子 10.1016/j.jmr.2017.08.010
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:29:04.046847
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3