WEKO3
アイテム
Long-term outcomes after carbon-ion radiotherapy for oral mucosal malignant melanoma.
https://repo.qst.go.jp/records/48315
https://repo.qst.go.jp/records/483158d4675cc-6967-4053-9956-d7c93a026667
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-08-21 | |||||
タイトル | ||||||
タイトル | Long-term outcomes after carbon-ion radiotherapy for oral mucosal malignant melanoma. | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Naganawa, Kensuke
× Naganawa, Kensuke× Koto, Masashi× Takagi, Ryo× Hasegawa, Azusa× Ikawa, Hiroaki× Shimozato, Kazuo× Kamada, Tadashi× Okamoto, Yoshitaka× 長縄 憲亮× 小藤 昌志× 高木 亮× 長谷川 安都佐× 伊川 裕明× 鎌田 正× 岡本 美孝 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Oral mucosal malignant melanoma (OMM) is extremely rare and has a poor prognosis. Owing to its rarity, it has not yet been possible to establish an optimal treatment modality. The objective of this study was to evaluate the long-term efficacy of carbon-ion radiotherapy (C-ion RT) for OMM. Between 1997 and 2013, 19 patients with OMM were treated with C-ion RT alone. Patient ages ranged from 44 to 84 years (median, 69 years). Nine men and 10 women were included. OMMs were restaged in accordance with the seventh edition of the tumour/node/metastasis (TNM) Staging System of the International Union Against Cancer. Before treatment, 14 patients had T3 disease and 5 had T4a disease. Three patients were classified as having N1 disease. All patients were classified as having M0. The hard palate was the most frequently involved oral subsite. All patients were treated with 57.6 Gy (relative biological effectiveness) in 16 fractions. The median follow-up period was 61 months (range, 8-190 months). The 5-year local control, overall survival and progression-free survival rates were 89.5%, 57.4% and 51.6%, respectively. For local control and overall survival, T classification was found to be a significant prognostic factor. Grade 2 and 3 osteoradionecrosis was observed in three and four patients, respectively. The presence of teeth within the planning target volume was a significant risk factor for developing osteoradionecrosis. C-ion RT was an effective treatment option with acceptable toxicity for OMM. | |||||
書誌情報 |
Journal of radiation research 巻 58, 号 4, p. 517-522, 発行日 2016-12 |
|||||
出版者 | ||||||
出版者 | Oxford University Press | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0449-3060 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 28028129 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1093/jrr/rrw117 |