WEKO3
アイテム
Multicentre dose audit for clinical trials of radiation therapy in Asia
https://repo.qst.go.jp/records/48305
https://repo.qst.go.jp/records/48305658ca629-a0a8-4a27-a886-f4e6466be863
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-08-21 | |||||
タイトル | ||||||
タイトル | Multicentre dose audit for clinical trials of radiation therapy in Asia | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
水野, 秀之
× 水野, 秀之× 福田, 茂一× 福村, 明史× Nakamura, Yuzuru-Kutsutani× Jianping, Cao× Cho, Chul-Koo× Supriana, Nana× Anh, Dung To× Joy, Calaguas Miriam× Beena, Devi C.R.× Chansilpa, Yaowalak× Akhter, Banu Parvin× Riaz, Masooma× Esentayeva, Surya× 加藤, 眞吾× 唐澤, 久美子× 辻井, 博彦× 水野 秀之× 福田 茂一× 福村 明史× 加藤 眞吾× 唐澤 久美子× 辻井 博彦 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A dose audit of 16 facilities in 11 countries has been performed within the framework of the Forum for Nuclear Cooperation in Asia (FNCA) quality assurance program. The quality of radiation dosimetry varies because of the large variation in radiation therapy among the participating countries. One of the most important aspects of international multicentre clinical trials is uniformity of absolute dose between centres. The National Institute of Radiological Sciences (NIRS) in Japan has conducted a dose audit of participating countries since 2006 by using radiophotoluminescent glass dosimeters (RGDs). RGDs have been successfully applied to a domestic postal dose audit in Japan. The authors used the same audit system to perform a dose audit of the FNCA countries. The average and standard deviation of the relative deviation between the measured and intended dose among 46 beams was 0.4% and 1.5% (k = 1), respectively. This is an excellent level of uniformity for the multicountry data. However, of the 46 beams measured, a single beam exceeded the permitted tolerance level of ±5%. We investigated the cause for this and solved the problem. This event highlights the importance of external audits in radiation therapy. |
|||||
書誌情報 |
Journal of Radiation Research 巻 58, 号 3, p. 372-377, 発行日 2016-11 |
|||||
出版者 | ||||||
出版者 | OXFORD | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1349-9157 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 27864507 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1093/jrr/rrw108 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://academic.oup.com/jrr/article-lookup/doi/10.1093/jrr/rrw108 | |||||
関連名称 | https://academic.oup.com/jrr/article-lookup/doi/10.1093/jrr/rrw108 |