Design and performance of daily quality assurance system for carbon ion therapy at NIRS

https://repo.qst.go.jp/records/48244
https://repo.qst.go.jp/records/48244
643831b9-8d78-4a5f-a1c4-f622691e8b4d
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-07-31
タイトル
タイトル Design and performance of daily quality assurance system for carbon ion therapy at NIRS
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 早乙女, 直也

× 早乙女, 直也

WEKO 484817

早乙女, 直也

Search repository
古川, 卓司

× 古川, 卓司

WEKO 484818

古川, 卓司

Search repository
原, 洋介

× 原, 洋介

WEKO 484819

原, 洋介

Search repository
水島, 康太

× 水島, 康太

WEKO 484820

水島, 康太

Search repository
丹正, 亮平

× 丹正, 亮平

WEKO 484821

丹正, 亮平

Search repository
皿谷, 有一

× 皿谷, 有一

WEKO 484822

皿谷, 有一

Search repository
白井, 敏之

× 白井, 敏之

WEKO 484823

白井, 敏之

Search repository
野田, 耕司

× 野田, 耕司

WEKO 484824

野田, 耕司

Search repository
早乙女 直也

× 早乙女 直也

WEKO 484825

en 早乙女 直也

Search repository
古川 卓司

× 古川 卓司

WEKO 484826

en 古川 卓司

Search repository
原 洋介

× 原 洋介

WEKO 484827

en 原 洋介

Search repository
水島 康太

× 水島 康太

WEKO 484828

en 水島 康太

Search repository
丹正 亮平

× 丹正 亮平

WEKO 484829

en 丹正 亮平

Search repository
皿谷 有一

× 皿谷 有一

WEKO 484830

en 皿谷 有一

Search repository
白井 敏之

× 白井 敏之

WEKO 484831

en 白井 敏之

Search repository
野田 耕司

× 野田 耕司

WEKO 484832

en 野田 耕司

Search repository
抄録
内容記述タイプ Abstract
内容記述 At National Institute of Radiological Sciences (NIRS), we have been commissioning a rotating-gantry system for carbon-ion radiotherapy. This rotating gantry can transport heavy ions at 430 MeV/u to an isocenter with irradiation angles of ±180 that can rotate around the patient so that the tumor can be irradiated from any direction. A three-dimensional pencil-beam scanning irradiation system equipped with the rotating gantry enables the optimal use of physical characteristics of carbon ions to provide accurate treatment. To ensure the treatment quality using such a complex system, the calibration of the primary dose monitor, output check, range check, dose rate check, machine safety check, and some mechanical tests should be performed efficiently. For this purpose, we have developed a measurement system dedicated for quality assurance (QA) of this gantry system: the Daily QA system. The system consists of an ionization chamber system and a scintillator system. The ionization chamber system is used for the calibration of the primary dose monitor, output check, and dose rate check, and the scintillator system is used for the range check, isocenter, and gantry angle. The performance of the Daily QA system was verified by a beam test. The stability of the output was within 0.5%, and the range was within 0.5 mm. The coincidence of the coordinates between the patient-positioning system and the irradiation system was verified using the Daily QA system. Our present findings verified that the new Daily QA system for a rotating gantry is capable of verifying the irradiation system with sufficient accuracy.
書誌情報 Nuclear Instruments and Methods in Physics Research Section B

巻 406, 号 A, p. 356-360, 発行日 2017-03
出版者
出版者 Elsevier Science
ISSN
収録物識別子タイプ ISSN
収録物識別子 0168-583X
DOI
識別子タイプ DOI
関連識別子 10.1016/j.nimb.2017.03.059
関連サイト
識別子タイプ URI
関連識別子 http://www.sciencedirect.com/science/article/pii/S0168583X17302987
関連名称 http://www.sciencedirect.com/science/article/pii/S0168583X17302987
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:30:19.794930
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3