Design and performance of daily quality assurance system for carbon ion therapy at NIRS
https://repo.qst.go.jp/records/48244
https://repo.qst.go.jp/records/48244643831b9-8d78-4a5f-a1c4-f622691e8b4d
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-07-31 | |||||
タイトル | ||||||
タイトル | Design and performance of daily quality assurance system for carbon ion therapy at NIRS | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
早乙女, 直也
× 早乙女, 直也× 古川, 卓司× 原, 洋介× 水島, 康太× 丹正, 亮平× 皿谷, 有一× 白井, 敏之× 野田, 耕司× 早乙女 直也× 古川 卓司× 原 洋介× 水島 康太× 丹正 亮平× 皿谷 有一× 白井 敏之× 野田 耕司 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | At National Institute of Radiological Sciences (NIRS), we have been commissioning a rotating-gantry system for carbon-ion radiotherapy. This rotating gantry can transport heavy ions at 430 MeV/u to an isocenter with irradiation angles of ±180 that can rotate around the patient so that the tumor can be irradiated from any direction. A three-dimensional pencil-beam scanning irradiation system equipped with the rotating gantry enables the optimal use of physical characteristics of carbon ions to provide accurate treatment. To ensure the treatment quality using such a complex system, the calibration of the primary dose monitor, output check, range check, dose rate check, machine safety check, and some mechanical tests should be performed efficiently. For this purpose, we have developed a measurement system dedicated for quality assurance (QA) of this gantry system: the Daily QA system. The system consists of an ionization chamber system and a scintillator system. The ionization chamber system is used for the calibration of the primary dose monitor, output check, and dose rate check, and the scintillator system is used for the range check, isocenter, and gantry angle. The performance of the Daily QA system was verified by a beam test. The stability of the output was within 0.5%, and the range was within 0.5 mm. The coincidence of the coordinates between the patient-positioning system and the irradiation system was verified using the Daily QA system. Our present findings verified that the new Daily QA system for a rotating gantry is capable of verifying the irradiation system with sufficient accuracy. | |||||
書誌情報 |
Nuclear Instruments and Methods in Physics Research Section B 巻 406, 号 A, p. 356-360, 発行日 2017-03 |
|||||
出版者 | ||||||
出版者 | Elsevier Science | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0168-583X | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.nimb.2017.03.059 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.sciencedirect.com/science/article/pii/S0168583X17302987 | |||||
関連名称 | http://www.sciencedirect.com/science/article/pii/S0168583X17302987 |