ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

RBE study using solid state microdosimetry in heavy ion therapy

https://repo.qst.go.jp/records/48207
https://repo.qst.go.jp/records/48207
0064fa09-e7dd-4847-8d7c-478f8ba1ccd2
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-07-25
タイトル
タイトル RBE study using solid state microdosimetry in heavy ion therapy
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 BOLST, David

× BOLST, David

WEKO 484288

BOLST, David

Search repository
Tran, Thuy Linh

× Tran, Thuy Linh

WEKO 484289

Tran, Thuy Linh

Search repository
Chartier, Lachlan

× Chartier, Lachlan

WEKO 484290

Chartier, Lachlan

Search repository
Prokopovich, Anthony

× Prokopovich, Anthony

WEKO 484291

Prokopovich, Anthony

Search repository
Pogossov, Alex

× Pogossov, Alex

WEKO 484292

Pogossov, Alex

Search repository
Guatelli, Susanna

× Guatelli, Susanna

WEKO 484293

Guatelli, Susanna

Search repository
Reinhard, Mark

× Reinhard, Mark

WEKO 484294

Reinhard, Mark

Search repository
Petasecca, Marco

× Petasecca, Marco

WEKO 484295

Petasecca, Marco

Search repository
Lerch, Michael

× Lerch, Michael

WEKO 484296

Lerch, Michael

Search repository
松藤, 成弘

× 松藤, 成弘

WEKO 484297

松藤, 成弘

Search repository
Perevertaylo, Vladimir

× Perevertaylo, Vladimir

WEKO 484298

Perevertaylo, Vladimir

Search repository
Fleta, Celeste

× Fleta, Celeste

WEKO 484299

Fleta, Celeste

Search repository
Rosenfeld, Anatoly

× Rosenfeld, Anatoly

WEKO 484300

Rosenfeld, Anatoly

Search repository
Jackson, Michael

× Jackson, Michael

WEKO 484301

Jackson, Michael

Search repository
Pellegrini, Giulio

× Pellegrini, Giulio

WEKO 484302

Pellegrini, Giulio

Search repository
BOLST David

× BOLST David

WEKO 484303

en BOLST David

Search repository
Tran Thuy Linh

× Tran Thuy Linh

WEKO 484304

en Tran Thuy Linh

Search repository
Chartier Lachlan

× Chartier Lachlan

WEKO 484305

en Chartier Lachlan

Search repository
Prokopovich Anthony

× Prokopovich Anthony

WEKO 484306

en Prokopovich Anthony

Search repository
Petasecca Marco

× Petasecca Marco

WEKO 484307

en Petasecca Marco

Search repository
松藤 成弘

× 松藤 成弘

WEKO 484308

en 松藤 成弘

Search repository
抄録
内容記述タイプ Abstract
内容記述 The response of two types of 10 mm thick silicon-on-insulator (SOI) detectors in a 12C ion therapy beam with extremely high spatial resolution are presented in this work. The two detectors used are the “bridge” microdosimeter with isolated 3D sensitive volumes (SVs) and the ultra-thin 3D (U3DTHIN) detector with nþ and pþ 3D columnar structures. Both detectors were investigated at various depths in a water phantom along the central axis of the spread-out Brag peak (SOBP) of a 290 MeV/u 12C ion beam at the Heavy Ion Medical Accelerator in Chiba, Japan. Based on the Microdosimetric Kinetic (MK) model and the microdosimetric quantities measured with the two detectors, the relative biological effectiveness (RBE) values were derived and compared to results obtained with the tissue-equivalent proportional counter (TEPC). Derived RBE10 values obtained with the U3DTHIN detector were considerably higher
than those obtained with the bridge microdosimeter and the TEPC along the SOBP. Due to the high spatial resolution of the microdosimeters, more detailed measurements were obtained at the end of the SOBP compared to the TEPC. The maximum derived RBE10 found using the U3DTHIN detector and bridge
microdosimeter were approximately 2.66 and 2.58, respectively which are higher than the RBE10 value of 2.35 obtained with the TEPC due to the lack of high spatial resolution in the TEPC. The discrepancy in the results obtained using the two detectors is due to the difference in geometry of the SVs in the two detectors. This work presents an application of different types of SOI micodosimeters in a 12C ion therapy beam and has demonstrated that the microdosimeter with micron sized 3D SVs is more desirable for accurate lineal energy measurement and RBE determination. Silicon microdosimetry has demonstrated a simple, fast and accurate method for routine Quality Assurance in charged particle therapy.
書誌情報 Radiation Measurements

発行日 2017-03
出版者
出版者 Elsevier
DOI
識別子タイプ DOI
関連識別子 10.1016/j.radmeas.2017.02.008
関連サイト
識別子タイプ DOI
関連識別子 http://dx.doi.org/10.1016/j.radmeas.2017.02.008
関連名称 http://dx.doi.org/10.1016/j.radmeas.2017.02.008
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:30:43.196740
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3