  1. 原著論文

Analysis of the cooldwon of the ITER central solenoid model coil and insert coil

https://repo.qst.go.jp/records/48194
https://repo.qst.go.jp/records/48194
87a03c86-e99d-40fd-9d80-bc25b7f90e2b
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-07-25
タイトル
タイトル Analysis of the cooldwon of the ITER central solenoid model coil and insert coil
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Bonifetto, R

× Bonifetto, R

WEKO 484101

Bonifetto, R

Search repository
Brighenti, A

× Brighenti, A

WEKO 484102

Brighenti, A

Search repository
礒野, 高明

× 礒野, 高明

WEKO 484103

礒野, 高明

Search repository
Martovetsky, N

× Martovetsky, N

WEKO 484104

Martovetsky, N

Search repository
河野, 勝己

× 河野, 勝己

WEKO 484105

河野, 勝己

Search repository
Savoldi, L

× Savoldi, L

WEKO 484106

Savoldi, L

Search repository
Zanino, R

× Zanino, R

WEKO 484107

Zanino, R

Search repository
礒野 高明

× 礒野 高明

WEKO 484108

en 礒野 高明

Search repository
河野 勝己

× 河野 勝己

WEKO 484109

en 河野 勝己

Search repository
抄録
内容記述タイプ Abstract
内容記述 A series of superconducting insert coils (ICs) made of different materials has been tested since 2000 at JAEA Naka in the bore of the central solenoid model coil at fields up to 13 T and currents up to several tens of kA, fully epresentative of the ITER operating conditions. Here we focus on the 2015 test of the presently last IC of the series, the central solenoid (CS) insert coil,
which was aimed at confirming the performance and properties of the Nb3Sn conductor, manufactured in Japan and used to wind the ITER CS modules in the US. As typical for these large scale applications, the cooldown (CD) from ambient to supercritical He temperature may take a long time, of the order of several weeks, so that it should be useful, also in the perspective of future IC tests, to optimize it. To that purpose, a comprehensive CD model implemented in the 4C code is developed and presented in this paper. The model is validated against the experimental data of an actual CD scenario, showing a very good agreement between simulation and measurements, from 300 to 4.5 K. The maximum temperature difference across the coil, which can only be roughly estimated from the measurements, is then extracted from the results of the simulation and shown to be much larger than the maximum value of 50 K, prescribed on the basis of the allowable thermal stress on the materials. An optimized CD scenario is finally designed using the model for the initial phase of the CD between 300 and 80 K, which allows reducing the needed time by ∼20%, while still satisfying the major constraints. Recommendations are also given for a better location/choice of the thermometers to be used for the monitoring of the maximum temperature difference across the coil.
書誌情報 Superconductor Science and Technology

巻 30, 号 1, p. 015015-1-015015-17, 発行日 2016-11
出版者
出版者 IOP Publishing
DOI
識別子タイプ DOI
関連識別子 10.1088/0953-2048/30/1/015015
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:30:52.525855
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3