ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

RENEB intercomparisons applying the conventional Dicentric Chromosome Assay (DCA)

https://repo.qst.go.jp/records/48127
https://repo.qst.go.jp/records/48127
1e349695-2c51-4f77-a9ce-97f88d5600ec
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-07-20
タイトル
タイトル RENEB intercomparisons applying the conventional Dicentric Chromosome Assay (DCA)
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Oestreicher, Ursula

× Oestreicher, Ursula

WEKO 483260

Oestreicher, Ursula

Search repository
Suto, Yumiko

× Suto, Yumiko

WEKO 483261

Suto, Yumiko

Search repository
Wojcik, Andrzej

× Wojcik, Andrzej

WEKO 483262

Wojcik, Andrzej

Search repository
al., et

× al., et

WEKO 483263

al., et

Search repository
數藤 由美子

× 數藤 由美子

WEKO 483264

en 數藤 由美子

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose: Two quality controlled inter-laboratory exercises were organized within the EU project ‘Realizing the European Network of Biodosimetry (RENEB)’ to further optimize the dicentric chromosome assay (DCA) and to identify needs for training and harmonization activities within the RENEB network.
Materials and methods: The general study design included blood shipment, sample processing, analysis of chromosome aberrations and radiation dose assessment. After manual scoring of dicentric chromosomes in different cell numbers dose estimations and corresponding 95% confidence intervals were submitted by the participants.
Results: The shipment of blood samples to the partners in the European Community (EU) were performed successfully. Outside the EU unacceptable delays occurred. The results of the dose estimation demonstrate a very successful classification of the blood samples in medically relevant groups. In comparison to the 1st exercise the 2nd intercomparison showed an improvement in the accuracy of dose estimations especially for the high dose point.
Conclusions: In case of a large-scale radiological incident, the pooling of ressources by networks can enhance the rapid classification of individuals in medically relevant treatment groups based on the DCA. The performance of the RENEB network as a whole has clearly benefited from harmonization processes and specific training activities for the network partners.
書誌情報 International Journal of Radiation Biology

巻 93, 号 1, p. 20-29, 発行日 2016-10
出版者
出版者 Taylor & Francic
ISSN
収録物識別子タイプ ISSN
収録物識別子 0955-3002
DOI
識別子タイプ DOI
関連識別子 10.1080/09553002.2016.1233370
関連サイト
識別子タイプ URI
関連識別子 http://www.tandfonline.com/doi/full/10.1080/09553002.2016.1233370
関連名称 http://www.tandfonline.com/doi/full/10.1080/09553002.2016.1233370
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:31:39.725080
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3