Measurement of radon in air using a radon-218Po calibration curve determined by an absorptive non-volatile liquid scintillator

https://repo.qst.go.jp/records/48082
https://repo.qst.go.jp/records/48082
c209af66-ae1a-4a75-b7d3-caff92976567
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-07-12
タイトル
タイトル Measurement of radon in air using a radon-218Po calibration curve determined by an absorptive non-volatile liquid scintillator
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kato, Takahisa

× Kato, Takahisa

WEKO 482780

Kato, Takahisa

Search repository
ミロソラフ, ヤニック

× ミロソラフ, ヤニック

WEKO 482781

ミロソラフ, ヤニック

Search repository
神田, 玲子

× 神田, 玲子

WEKO 482782

神田, 玲子

Search repository
Ishikawa, Tetsuo

× Ishikawa, Tetsuo

WEKO 482783

Ishikawa, Tetsuo

Search repository
Kawase, Masaya

× Kawase, Masaya

WEKO 482784

Kawase, Masaya

Search repository
Kawamoto, Takuo

× Kawamoto, Takuo

WEKO 482785

Kawamoto, Takuo

Search repository
ミロソラフ ヤニック

× ミロソラフ ヤニック

WEKO 482786

en ミロソラフ ヤニック

Search repository
神田 玲子

× 神田 玲子

WEKO 482787

en 神田 玲子

Search repository
抄録
内容記述タイプ Abstract
内容記述 This work reports a novel method for determining 222Rn (radon) in air using a radon-218Po calibration curve constructed by an absorbable non-volatile liquid scintillator (NVLS). The ability of this method to detect low natural concentrations of radon was confirmed from linear extrapolation of the curve between 500 and 8000 Bq/m3. The calibration curve was created from data obtained from measurements performed in a radon calibration chamber at the National Institute of Radiological Science (NIRS) by using the least-squares method. The line had high precision and stability, and the required detection time was less than that of 214Po. An absorptive NVLS was used to collect radon and was found to be highly advantageous for α-spectrometry liquid scintillation measurements. Variations of the Ostwald coefficient due to changes in temperature and humidity, which affect radon absorption, were investigated and discussed.
書誌情報 Radiation Measurements

巻 95, p. 25-30, 発行日 2016-10
出版者
出版者 Elsevier
ISSN
収録物識別子タイプ ISSN
収録物識別子 1350-4487
DOI
識別子タイプ DOI
関連識別子 10.1016/j.radmeas.2016.10.001
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:32:11.854712
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3