Simulation study of a D-shape PET scanner for improved sensitivity and reduced cost in whole-body imaging

https://repo.qst.go.jp/records/48046
https://repo.qst.go.jp/records/48046
815f9718-1e36-4534-bebd-f095b33a3fc8
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-06-07
タイトル
タイトル Simulation study of a D-shape PET scanner for improved sensitivity and reduced cost in whole-body imaging
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Ahmed, Abdella

× Ahmed, Abdella

WEKO 482451

Ahmed, Abdella

Search repository
Tashima, Hideaki

× Tashima, Hideaki

WEKO 482452

Tashima, Hideaki

Search repository
Yamaya, Taiga

× Yamaya, Taiga

WEKO 482453

Yamaya, Taiga

Search repository
Ahmed Abdella Mohammednur

× Ahmed Abdella Mohammednur

WEKO 482454

en Ahmed Abdella Mohammednur

Search repository
田島 英朗

× 田島 英朗

WEKO 482455

en 田島 英朗

Search repository
山谷 泰賀

× 山谷 泰賀

WEKO 482456

en 山谷 泰賀

Search repository
抄録
内容記述タイプ Abstract
内容記述 Much research effort is being made to increase the sensitivity and improve
the imaging performance of positron emission tomography (PET) scanners.
Conventionally, sensitivity can be increased by increasing the number of
detector rings in the axial direction (but at high cost) or reducing the diameter
of the scanner (with the disadvantages of reducing the space for patients and
degrading the spatial resolution due to the parallax error). In this study, we
proposed a PET scanner with a truncated ring and an array of detectors that
can be arranged in a straight line below the bed. We called this system ‘D-PET’
as it resembles the letter ‘D’ when it is rotated by 90° in the counterclockwise
direction. The basic design idea was to cut the unused space under the patient’s
bed; this area is usually not in use in clinical diagnosis. We conducted Monte
Carlo simulations of the D-PET scanner and compared its performance with
a cylindrical PET scanner. The scanners were constructed from 4-layer depthof-
interaction detectors which consisted of a 16 × 16 × 4 LYSO crystal array
with dimensions of 2.85 × 2.85 × 5 mm3. The results showed that the D-PET
had an increase in sensitivity and peak-NECR of 30% and 18%, respectively.
The D-PET had low noise in the reconstructed images throughout the fieldof-
view compared to the cylindrical PET. These were achieved while keeping
sufficient space for the patient, and also without a severe effect on the spatial
resolution. Furthermore, the number of detectors (and hence the cost) of the
D-PET scanner was reduced by 12% compared to the cylindrical PET scanner.
書誌情報 Physics in Medicine and Biology

巻 62, 号 10, p. 4107-4117, 発行日 2017-04
ISSN
収録物識別子タイプ ISSN
収録物識別子 1361-6560
DOI
識別子タイプ DOI
関連識別子 10.1088/1361-6560/aa6853
関連サイト
識別子タイプ DOI
関連識別子 https://doi.org/10.1088/1361-6560/aa6853
関連名称 https://doi.org/10.1088/1361-6560/aa6853
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:32:34.623874
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3