Simulation study of a D-shape PET scanner for improved sensitivity and reduced cost in whole-body imaging
https://repo.qst.go.jp/records/48046
https://repo.qst.go.jp/records/48046815f9718-1e36-4534-bebd-f095b33a3fc8
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-06-07 | |||||
タイトル | ||||||
タイトル | Simulation study of a D-shape PET scanner for improved sensitivity and reduced cost in whole-body imaging | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Ahmed, Abdella
× Ahmed, Abdella× Tashima, Hideaki× Yamaya, Taiga× Ahmed Abdella Mohammednur× 田島 英朗× 山谷 泰賀 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Much research effort is being made to increase the sensitivity and improve the imaging performance of positron emission tomography (PET) scanners. Conventionally, sensitivity can be increased by increasing the number of detector rings in the axial direction (but at high cost) or reducing the diameter of the scanner (with the disadvantages of reducing the space for patients and degrading the spatial resolution due to the parallax error). In this study, we proposed a PET scanner with a truncated ring and an array of detectors that can be arranged in a straight line below the bed. We called this system ‘D-PET’ as it resembles the letter ‘D’ when it is rotated by 90° in the counterclockwise direction. The basic design idea was to cut the unused space under the patient’s bed; this area is usually not in use in clinical diagnosis. We conducted Monte Carlo simulations of the D-PET scanner and compared its performance with a cylindrical PET scanner. The scanners were constructed from 4-layer depthof- interaction detectors which consisted of a 16 × 16 × 4 LYSO crystal array with dimensions of 2.85 × 2.85 × 5 mm3. The results showed that the D-PET had an increase in sensitivity and peak-NECR of 30% and 18%, respectively. The D-PET had low noise in the reconstructed images throughout the fieldof- view compared to the cylindrical PET. These were achieved while keeping sufficient space for the patient, and also without a severe effect on the spatial resolution. Furthermore, the number of detectors (and hence the cost) of the D-PET scanner was reduced by 12% compared to the cylindrical PET scanner. |
|||||
書誌情報 |
Physics in Medicine and Biology 巻 62, 号 10, p. 4107-4117, 発行日 2017-04 |
|||||