ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Determination of 107Pd in Pd Recovered by Laser-Induced Photoreduction for Inductively Coupled Plasma Mass Spectrometry

https://repo.qst.go.jp/records/47910
https://repo.qst.go.jp/records/47910
2c963be2-f071-44fe-a226-b910c980e79c
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-05-01
タイトル
タイトル Determination of 107Pd in Pd Recovered by Laser-Induced Photoreduction for Inductively Coupled Plasma Mass Spectrometry
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 浅井, 志保

× 浅井, 志保

WEKO 480961

浅井, 志保

Search repository
蓬田, 匠

× 蓬田, 匠

WEKO 480962

蓬田, 匠

Search repository
佐伯, 盛久

× 佐伯, 盛久

WEKO 480963

佐伯, 盛久

Search repository
大場, 弘則

× 大場, 弘則

WEKO 480964

大場, 弘則

Search repository
半澤有希子

× 半澤有希子

WEKO 480965

半澤有希子

Search repository
堀田拓摩

× 堀田拓摩

WEKO 480966

堀田拓摩

Search repository
北辻章浩

× 北辻章浩

WEKO 480967

北辻章浩

Search repository
佐伯 盛久

× 佐伯 盛久

WEKO 480968

en 佐伯 盛久

Search repository
大場 弘則

× 大場 弘則

WEKO 480969

en 大場 弘則

Search repository
抄録
内容記述タイプ Abstract
内容記述 Safety evaluation of a radioactive waste repository requires credible activity estimates confirmed by actual measurements. A long-lived radionuclide, 107Pd, which can be found in radioactive wastes, is one of the difficult to measure nuclides and results in a deficit in experimentally determined contents. In this study, a precipitation based separation method has been developed for the determination of 107Pd with inductively coupled plasma mass spectrometry. The photoreduction induced by pulsed laser irradiation at 355 nm provides short-time and one-step recovery of Pd. The proposed method was validated by applying it to a spent nuclear fuel sample. In order to efficiently recover Pd, a natural Pd standard was employed as the Pd carrier. Taking advantage of the absence of 102Pd in spent nuclear fuel, 102Pd in the Pd carrier was utilized as the internal standard. The chemical yield of Pd was about 90% with virtually no impurities, allowing accurate quantification of 107Pd. The amount of 107Pd in the Pd precipitate was 17.3 ± 0.7 ng, equivalent to 239 ± 9 ng per mg of 238U in the sample.
書誌情報 Analytical Chemistry

巻 88, 号 24, p. 12227-12233, 発行日 2016-11
出版者
出版者 American Chemical Society
DOI
識別子タイプ DOI
関連識別子 10.1021/acs.analchem.6b03286
戻る
0
views
See details
Views