{"_buckets": {"deposit": "84602217-adaa-4c08-b84e-cc76f1247377"}, "_deposit": {"created_by": 1, "id": "47890", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "47890"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00047890", "sets": ["1"]}, "author_link": ["480787", "480793", "480791", "480786", "480783", "480794", "480795", "480785", "480784", "480788", "480780", "480792", "480790", "480796", "480779", "480789", "480782", "480781"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2017-03", "bibliographicIssueDateType": "Issued"}, "bibliographic_titles": [{"bibliographic_title": "Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Since 2011, a three-dimensional (3D) scanning irradiation system has been utilized for treatments at the National Institute of Radiological Sciences-Heavy Ion Medical Accelerator in Chiba (NIRS-HIMAC). In 2012, a hybrid depth scanning method was introduced for the depth direction, in which 11 discrete beam energies are used in conjunction with the range shifter. To suppress beam spread due to multiple scattering and nuclear reactions, we then developed a full energy scanning method. Accelerator tuning and beam commissioning tests prior to a treatment with this method are time-consuming, however.\nWe therefore devised a new approach to obtain the pencil beam dataset, including consideration of the contribution of large-angle scattered (LAS) particles, which reduces the time spent on beam data preparation. The accuracy of 3D dose delivery using this new approach was verified by measuring the dose distributions for different target volumes. Results confirmed that the measured dose distributions agreed well with calculated doses. Following this evaluation, treatments using the full energy scanning method were commenced in September 2015.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Elsevier"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1016/j.nimb.2017.02.052", "subitem_relation_type_select": "DOI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0168-583X", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Hara, Yousuke"}], "nameIdentifiers": [{"nameIdentifier": "480779", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Furukawa, Takuji"}], "nameIdentifiers": [{"nameIdentifier": "480780", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Mizushima, Kota"}], "nameIdentifiers": [{"nameIdentifier": "480781", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Inaniwa, Taku"}], "nameIdentifiers": [{"nameIdentifier": "480782", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Saotome, Naoya"}], "nameIdentifiers": [{"nameIdentifier": "480783", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tansho, Ryohei"}], "nameIdentifiers": [{"nameIdentifier": "480784", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Saraya, Yuichi"}], "nameIdentifiers": [{"nameIdentifier": "480785", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shirai, Toshiyuki"}], "nameIdentifiers": [{"nameIdentifier": "480786", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Noda, Koji"}], "nameIdentifiers": [{"nameIdentifier": "480787", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "原 洋介", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "480788", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "古川 卓司", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "480789", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "水島 康太", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "480790", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "稲庭 拓", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "480791", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "早乙女 直也", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "480792", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "丹正 亮平", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "480793", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "皿谷 有一", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "480794", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "白井 敏之", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "480795", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "野田 耕司", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "480796", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Commissioning of full energy scanning irradiation with carbon-ion beams ranging from 55.6 to 430 MeV/u at the NIRS-HIMAC", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Commissioning of full energy scanning irradiation with carbon-ion beams ranging from 55.6 to 430 MeV/u at the NIRS-HIMAC"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/47890", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-04-27"}, "publish_date": "2017-04-27", "publish_status": "0", "recid": "47890", "relation": {}, "relation_version_is_last": true, "title": ["Commissioning of full energy scanning irradiation with carbon-ion beams ranging from 55.6 to 430 MeV/u at the NIRS-HIMAC"], "weko_shared_id": -1}
  1. 原著論文

Commissioning of full energy scanning irradiation with carbon-ion beams ranging from 55.6 to 430 MeV/u at the NIRS-HIMAC

https://repo.qst.go.jp/records/47890
https://repo.qst.go.jp/records/47890
44744ab4-2e08-430b-8c81-f5733aaefe57
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-04-27
タイトル
タイトル Commissioning of full energy scanning irradiation with carbon-ion beams ranging from 55.6 to 430 MeV/u at the NIRS-HIMAC
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Hara, Yousuke

× Hara, Yousuke

WEKO 480779

Hara, Yousuke

Search repository
Furukawa, Takuji

× Furukawa, Takuji

WEKO 480780

Furukawa, Takuji

Search repository
Mizushima, Kota

× Mizushima, Kota

WEKO 480781

Mizushima, Kota

Search repository
Inaniwa, Taku

× Inaniwa, Taku

WEKO 480782

Inaniwa, Taku

Search repository
Saotome, Naoya

× Saotome, Naoya

WEKO 480783

Saotome, Naoya

Search repository
Tansho, Ryohei

× Tansho, Ryohei

WEKO 480784

Tansho, Ryohei

Search repository
Saraya, Yuichi

× Saraya, Yuichi

WEKO 480785

Saraya, Yuichi

Search repository
Shirai, Toshiyuki

× Shirai, Toshiyuki

WEKO 480786

Shirai, Toshiyuki

Search repository
Noda, Koji

× Noda, Koji

WEKO 480787

Noda, Koji

Search repository
原 洋介

× 原 洋介

WEKO 480788

en 原 洋介

Search repository
古川 卓司

× 古川 卓司

WEKO 480789

en 古川 卓司

Search repository
水島 康太

× 水島 康太

WEKO 480790

en 水島 康太

Search repository
稲庭 拓

× 稲庭 拓

WEKO 480791

en 稲庭 拓

Search repository
早乙女 直也

× 早乙女 直也

WEKO 480792

en 早乙女 直也

Search repository
丹正 亮平

× 丹正 亮平

WEKO 480793

en 丹正 亮平

Search repository
皿谷 有一

× 皿谷 有一

WEKO 480794

en 皿谷 有一

Search repository
白井 敏之

× 白井 敏之

WEKO 480795

en 白井 敏之

Search repository
野田 耕司

× 野田 耕司

WEKO 480796

en 野田 耕司

Search repository
抄録
内容記述タイプ Abstract
内容記述 Since 2011, a three-dimensional (3D) scanning irradiation system has been utilized for treatments at the National Institute of Radiological Sciences-Heavy Ion Medical Accelerator in Chiba (NIRS-HIMAC). In 2012, a hybrid depth scanning method was introduced for the depth direction, in which 11 discrete beam energies are used in conjunction with the range shifter. To suppress beam spread due to multiple scattering and nuclear reactions, we then developed a full energy scanning method. Accelerator tuning and beam commissioning tests prior to a treatment with this method are time-consuming, however.
We therefore devised a new approach to obtain the pencil beam dataset, including consideration of the contribution of large-angle scattered (LAS) particles, which reduces the time spent on beam data preparation. The accuracy of 3D dose delivery using this new approach was verified by measuring the dose distributions for different target volumes. Results confirmed that the measured dose distributions agreed well with calculated doses. Following this evaluation, treatments using the full energy scanning method were commenced in September 2015.
書誌情報 Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms

発行日 2017-03
出版者
出版者 Elsevier
ISSN
収録物識別子タイプ ISSN
収録物識別子 0168-583X
DOI
識別子タイプ DOI
関連識別子 10.1016/j.nimb.2017.02.052
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:34:24.953048
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3