ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Detection of a gas region in a human body across a therapeutic carbon beam by measuring low-energy photons

https://repo.qst.go.jp/records/47854
https://repo.qst.go.jp/records/47854
20b36cfb-cee9-41ce-8867-efd30a4130b7
Item type 学術雑誌論文 / Journal Article(1)
公開日 2016-10-04
タイトル
タイトル Detection of a gas region in a human body across a therapeutic carbon beam by measuring low-energy photons
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 山口, 充孝

× 山口, 充孝

WEKO 744252

山口, 充孝

Search repository
長尾, 悠人

× 長尾, 悠人

WEKO 744253

長尾, 悠人

Search repository
河地, 有木

× 河地, 有木

WEKO 744254

河地, 有木

Search repository
佐藤, 隆博

× 佐藤, 隆博

WEKO 744255

佐藤, 隆博

Search repository
藤巻, 秀

× 藤巻, 秀

WEKO 744256

藤巻, 秀

Search repository
神谷, 富裕

× 神谷, 富裕

WEKO 744257

神谷, 富裕

Search repository
鳥飼, 幸太

× 鳥飼, 幸太

WEKO 744258

鳥飼, 幸太

Search repository
島田, 博文

× 島田, 博文

WEKO 744259

島田, 博文

Search repository
菅井, 裕之

× 菅井, 裕之

WEKO 744260

菅井, 裕之

Search repository
酒井, 真理

× 酒井, 真理

WEKO 744261

酒井, 真理

Search repository
荒川, 和夫

× 荒川, 和夫

WEKO 744262

荒川, 和夫

Search repository
中野, 隆史

× 中野, 隆史

WEKO 744263

中野, 隆史

Search repository
Yamaguchi, Mitsutaka

× Yamaguchi, Mitsutaka

WEKO 744264

en Yamaguchi, Mitsutaka

Search repository
Nagao, Yuuto

× Nagao, Yuuto

WEKO 744265

en Nagao, Yuuto

Search repository
Kawachi, Naoki

× Kawachi, Naoki

WEKO 744266

en Kawachi, Naoki

Search repository
Sato, Takahiro

× Sato, Takahiro

WEKO 744267

en Sato, Takahiro

Search repository
Fujimaki, Shiyuu

× Fujimaki, Shiyuu

WEKO 744268

en Fujimaki, Shiyuu

Search repository
Kamiya, Tomihiro

× Kamiya, Tomihiro

WEKO 744269

en Kamiya, Tomihiro

Search repository
Arakawa, Kazuo

× Arakawa, Kazuo

WEKO 744270

en Arakawa, Kazuo

Search repository
抄録
内容記述タイプ Abstract
内容記述 We studied feasibility of detection of a gap which is located across a beam track by measuring low-energy (63-68 keV) photons generated by beam irradiation. An experiment was performed with the Heavy Ion Medical Accelerator in Chiba (HIMAC). A C-12 beam having 290 MeV/u was injected on a target consisting of two acrylic blocks. These two blocks were placed with a 10-mm gap along the beam axis. A detection system consisting of a semiconductor detector, a lead collimator having a slit, and borated polyethylene blocks was placed on a movable stage to detect low-energy photons emitted perpendicularly to the beam axis. The position of the detection system was moved at 2-mm intervals along the beam axis. It was found that the yield of 63--68~keV photons was clearly correlated with the position of the detection system. The position at which the yield curve had the lowest value agreed with the gap position. We also confirmed that the experimental result was well reproduced by a Monte Carlo simulation that includes generation of secondary electron bremsstrahlung.
書誌情報 International Journal of PIXE

巻 26, 号 01n02, p. 61-72, 発行日 2016-12
出版者
出版者 World Scientific Publishing Company
DOI
識別子タイプ DOI
関連識別子 10.1142/S0129083516500078
関連サイト
識別子タイプ DOI
関連識別子 http://dx.doi.org/10.1142/S0129083516500078
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:57:58.270669
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3