Method for ultra-trace level 241Am determination in large size soil samples by SF-ICP-MS: with emphasis on the removal of spectral interferences and matrix effect

https://repo.qst.go.jp/records/47832
https://repo.qst.go.jp/records/47832
144ad18c-1f83-4e37-9242-896a27835b47
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-04-26
タイトル
タイトル Method for ultra-trace level 241Am determination in large size soil samples by SF-ICP-MS: with emphasis on the removal of spectral interferences and matrix effect
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Wang, Zhongtang

× Wang, Zhongtang

WEKO 480151

Wang, Zhongtang

Search repository
Zheng, Jian

× Zheng, Jian

WEKO 480152

Zheng, Jian

Search repository
Cao, Liguo

× Cao, Liguo

WEKO 480153

Cao, Liguo

Search repository
Tagami, Keiko

× Tagami, Keiko

WEKO 480154

Tagami, Keiko

Search repository
Uchida, Shigeo

× Uchida, Shigeo

WEKO 480155

Uchida, Shigeo

Search repository
王 鍾堂

× 王 鍾堂

WEKO 480156

en 王 鍾堂

Search repository
鄭 建

× 鄭 建

WEKO 480157

en 鄭 建

Search repository
田上 恵子

× 田上 恵子

WEKO 480158

en 田上 恵子

Search repository
内田 滋夫

× 内田 滋夫

WEKO 480159

en 内田 滋夫

Search repository
抄録
内容記述タイプ Abstract
内容記述 A new analytical method using SF-ICP-MS was developed for the determination of 241Am in large soil samples to provide realistic soil-plant transfer parameter data for dose assessment of nuclear waste disposal plans. We investigated four subjects: extraction behaviors of interfering elements (Bi, Tl, Hg, Pb, Hf and Pt) on DGA-N resin; soil matrix element removal (Mg, Fe, Al, K, Na) using Fe(OH)3, CaF2 and CaC2O4 co-precipitations; Am and rare earth elements (REEs) separation on DGA-N and TEVA resins; and optimization of the Aridus II–SF-ICP-MS analytical system for Am determination. Our method utilized conc. HNO3 to leach Am from 2-20 g soil samples. The CaC2O4 co-precipitation was used to remove major metals in soil, and followed by Am/interfering elements separation using the proposed UTEVA+DGA-N procedure. After a further separation of REEs on TEVA resin, 241Am was determined by Aridus II–SF-ICP-MS. This method eliminated the matrix effect in ICP-MS 241Am measurement for large soil samples. The high decontamination factors (DFs) of interfering elements enable their thorough removal from Am fraction, and in particular, the DF of Pu (7 × 105) was the highest ever reported in 241Am studies; thus, this method is capable of analyzing 241Pu-contaminated FDNPP-sourced soil samples. A low detection limit of 0.012 mBq/g for 241Am was achieved. The chemical recovery of Am (76% -82%) was very stable for soil samples. This method can be employed for the low level 241Am determination in large size soil samples that are contaminated with 241Pu.
書誌情報 Analytical Chemistry

巻 88, 号 14, p. 7387-7394, 発行日 2016-05
出版者
出版者 ACS Publications
DOI
識別子タイプ DOI
関連識別子 10.1021/acs.analchem.6b01934
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:35:03.311322
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3