WEKO3
アイテム
Impact of spillover from white matter by partial volume effect on quantification of amyloid deposition with [(11)C]PiB PET.
https://repo.qst.go.jp/records/47772
https://repo.qst.go.jp/records/4777289783c2a-f3f5-4ab4-8770-9e41b251e854
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-04-25 | |||||
タイトル | ||||||
タイトル | Impact of spillover from white matter by partial volume effect on quantification of amyloid deposition with [(11)C]PiB PET. | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Matsubara, Keisuke
× Matsubara, Keisuke× Ibaraki, Masanobu× Shimada, Hitoshi× Ikoma, Yoko× Suhara, Tetsuya× Kinoshita, Toshibumi× Ito, Hiroshi× 島田 斉× 須原 哲也× 伊藤 浩 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | High non-specific uptake of [(11)C]Pittsburgh compound B ([(11)C]PiB) in white matter and signal spillover from white matter, due to partial volume effects, confound radioactivity measured in positron emission tomography (PET) with [(11)C]PiB. We aimed to reveal the partial volume effect in absolute values of kinetic parameters for [(11)C]PiB, in terms of spillover from white matter. Dynamic data acquired in [(11)C]PiB PET scans with five healthy volunteers and eight patients with Alzheimer's disease were corrected with region-based and voxel-based partial volume corrections. Binding potential (BPND) was estimated using the two-tissue compartment model analysis with a plasma input function. Partial volume corrections significantly decreased cortical BPND values. The degree of decrease in healthy volunteers (-52.7 ± 5.8%) was larger than that in Alzheimer's disease patients (-11.9 ± 4.2%). The simulation demonstrated that white matter spillover signals due to the partial volume effect resulted in an overestimation of cortical BPND, with a greater degree of overestimation for lower BPND values. Thus, an overestimation due to partial volume effects is more severe in healthy volunteers than in Alzheimer's disease patients. Partial volume corrections may be useful for accurately quantifying Aβ deposition in cortical regions. | |||||
書誌情報 |
NeuroImage 巻 143, p. 316-324, 発行日 2016-09 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1053-8119 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 27639351 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.neuroimage.2016.09.028 |