Impact of spillover from white matter by partial volume effect on quantification of amyloid deposition with [(11)C]PiB PET.

https://repo.qst.go.jp/records/47772
https://repo.qst.go.jp/records/47772
89783c2a-f3f5-4ab4-8770-9e41b251e854
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-04-25
タイトル
タイトル Impact of spillover from white matter by partial volume effect on quantification of amyloid deposition with [(11)C]PiB PET.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Matsubara, Keisuke

× Matsubara, Keisuke

WEKO 479399

Matsubara, Keisuke

Search repository
Ibaraki, Masanobu

× Ibaraki, Masanobu

WEKO 479400

Ibaraki, Masanobu

Search repository
Shimada, Hitoshi

× Shimada, Hitoshi

WEKO 479401

Shimada, Hitoshi

Search repository
Ikoma, Yoko

× Ikoma, Yoko

WEKO 479402

Ikoma, Yoko

Search repository
Suhara, Tetsuya

× Suhara, Tetsuya

WEKO 479403

Suhara, Tetsuya

Search repository
Kinoshita, Toshibumi

× Kinoshita, Toshibumi

WEKO 479404

Kinoshita, Toshibumi

Search repository
Ito, Hiroshi

× Ito, Hiroshi

WEKO 479405

Ito, Hiroshi

Search repository
島田 斉

× 島田 斉

WEKO 479406

en 島田 斉

Search repository
須原 哲也

× 須原 哲也

WEKO 479407

en 須原 哲也

Search repository
伊藤 浩

× 伊藤 浩

WEKO 479408

en 伊藤 浩

Search repository
抄録
内容記述タイプ Abstract
内容記述 High non-specific uptake of [(11)C]Pittsburgh compound B ([(11)C]PiB) in white matter and signal spillover from white matter, due to partial volume effects, confound radioactivity measured in positron emission tomography (PET) with [(11)C]PiB. We aimed to reveal the partial volume effect in absolute values of kinetic parameters for [(11)C]PiB, in terms of spillover from white matter. Dynamic data acquired in [(11)C]PiB PET scans with five healthy volunteers and eight patients with Alzheimer's disease were corrected with region-based and voxel-based partial volume corrections. Binding potential (BPND) was estimated using the two-tissue compartment model analysis with a plasma input function. Partial volume corrections significantly decreased cortical BPND values. The degree of decrease in healthy volunteers (-52.7 ± 5.8%) was larger than that in Alzheimer's disease patients (-11.9 ± 4.2%). The simulation demonstrated that white matter spillover signals due to the partial volume effect resulted in an overestimation of cortical BPND, with a greater degree of overestimation for lower BPND values. Thus, an overestimation due to partial volume effects is more severe in healthy volunteers than in Alzheimer's disease patients. Partial volume corrections may be useful for accurately quantifying Aβ deposition in cortical regions.
書誌情報 NeuroImage

巻 143, p. 316-324, 発行日 2016-09
ISSN
収録物識別子タイプ ISSN
収録物識別子 1053-8119
PubMed番号
識別子タイプ PMID
関連識別子 27639351
DOI
識別子タイプ DOI
関連識別子 10.1016/j.neuroimage.2016.09.028
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:35:44.361856
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3