ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Amino acid transport system - A substrate predicts the therapeutic effects of particle radiotherapy

https://repo.qst.go.jp/records/47715
https://repo.qst.go.jp/records/47715
3680c9b2-7af9-40d5-a533-57abfe431494
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-04-19
タイトル
タイトル Amino acid transport system - A substrate predicts the therapeutic effects of particle radiotherapy
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Tomoya, Uehara

× Tomoya, Uehara

WEKO 478789

Tomoya, Uehara

Search repository
Mariko, Watanabe

× Mariko, Watanabe

WEKO 478790

Mariko, Watanabe

Search repository
Hiroyuki, Suzuki

× Hiroyuki, Suzuki

WEKO 478791

Hiroyuki, Suzuki

Search repository
Furusawa, Yoshiya

× Furusawa, Yoshiya

WEKO 478792

Furusawa, Yoshiya

Search repository
Yasushi, Arano

× Yasushi, Arano

WEKO 478793

Yasushi, Arano

Search repository
古澤 佳也

× 古澤 佳也

WEKO 478794

en 古澤 佳也

Search repository
抄録
内容記述タイプ Abstract
内容記述 Abstract: L-[methyl-11C]Methionine (11C-Met) is useful for estimating the therapeutic efficiencies of conventional radiotherapy and carbon-ion radiotherapy. Due to the short half-life of 11C, the development of other radionuclide-labeled probes, particularly those that afford similar diagnostic information to 11C-Met, is being sought. Since the energy-dependent cellular functions involved in 11C-Met reflect radiotherapeutic effects, we herein evaluated the activity of energy-dependent amino acid transport system A in order to estimate radiotherapeutic effects using the specific system A substrate, alpha-[1-14C]-methyl-aminoisobutyric acid (14C-MeAIB) because 18F- or 123I-labeled probes for system A have already been produced. Methods: A carbon-ion beam was used as the radiation source. Cellular growth and the accumulation of 14C-MeAIB or L-[14C-methyl]methionine (14C-Met) were evaluated over time in in vitro cultured human salivary gland (HSG) tumor cells (3 Gy) or in vivo murine xenografts of HSG tumors (6 or 25 Gy) before and after irradiation with the carbon-ion beam. Results: In an in vitro study, after 3-Gy irradiation dose, the uptakes of 14C-Met and 14C-MeAIB decreased over a 5-day period. In xenografts of HSG in mice, in vivo tumor re-growth was observed on day 10 after the 6-Gy irradiation dose, but was not detected after the 25-Gy irradiation dose. Consistent with these results, no significant differences were noted in the in vivo tumor uptake of 14C-MeAIB before and after the 6-Gy irradiation dose, whereas a significant decrease was observed after the 25-Gy irradiation dose. Conclusions: The results of the present study indicate that the activity of system A reflects the therapeutic efficacy of carbon-ion radiotherapy as well as 14C-Met. Therefore, 18F- or 123I-labeled probes for system A have potential as widely usable probes to evaluate the effects of tumor radiotherapy.
書誌情報 PLOS ONE

巻 12, 号 2, p. e0173096-1-e0173096-13, 発行日 2017-02
出版者
出版者 Public Library of Science
ISSN
収録物識別子タイプ ISSN
収録物識別子 1932-6203
PubMed番号
識別子タイプ PMID
関連識別子 28245294
DOI
識別子タイプ DOI
関連識別子 10.1371/journal.pone.0173096
関連サイト
識別子タイプ DOI
関連識別子 http://dx.doi.org/10.1371/journal.pone.0173096
関連名称 http://dx.doi.org/10.1371/journal.pone.0173096
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:36:21.099447
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3