Practical production of 61Cu using natural Co target and its simple purification with a chelating resin for 61Cu-ATSM

https://repo.qst.go.jp/records/47696
https://repo.qst.go.jp/records/47696
83ca3ca1-82a1-4775-8678-65a6cfd0df42
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-03-27
タイトル
タイトル Practical production of 61Cu using natural Co target and its simple purification with a chelating resin for 61Cu-ATSM
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Fukumura, Toshimitsu

× Fukumura, Toshimitsu

WEKO 478585

Fukumura, Toshimitsu

Search repository
Okada, Kazuhiro

× Okada, Kazuhiro

WEKO 478586

Okada, Kazuhiro

Search repository
Ferenc, Szelecsenyi

× Ferenc, Szelecsenyi

WEKO 478587

Ferenc, Szelecsenyi

Search repository
Kovacs, Zoltan

× Kovacs, Zoltan

WEKO 478588

Kovacs, Zoltan

Search repository
Suzuki, Kazutoshi

× Suzuki, Kazutoshi

WEKO 478589

Suzuki, Kazutoshi

Search repository
福村 利光

× 福村 利光

WEKO 478590

en 福村 利光

Search repository
Ferenc Szelecsenyi

× Ferenc Szelecsenyi

WEKO 478591

en Ferenc Szelecsenyi

Search repository
ゾルタン コバックス

× ゾルタン コバックス

WEKO 478592

en ゾルタン コバックス

Search repository
鈴木 和年

× 鈴木 和年

WEKO 478593

en 鈴木 和年

Search repository
抄録
内容記述タイプ Abstract
内容記述 Copper-61 (T-1/2 = 3.41 h) produced via the Co-59(alpha, 2n)Cu-61 nuclear reaction using natural Co target was isolated from the irradiated target by two methods developed here and applied for preparation of (Cu-61-ATSM) (Cu-61-diacetyl-bis(N-4-methylthiosemicarbazone)), known as an imaging agent of hypoxic tissue. A commercially available cobalt disk (thickness: 125 mum) was irradiated with 40 MeV (37.9 MeV on target) a particles, then treated with conc. HNO3, and the Cu-61 was separated by two different methods, i.e. a two column method using a cation and an anion exchange column; and a one Column method using a column packed with chelating resin, Chelex 100. Both separation methods gave satisfactory results, though the latter method was superior because of the simplicity of the apparatus, the separation procedure and somewhat shorter processing time. Around 1.1 GBq of 61Cu(2+) were obtained with >95% yield (decay corrected) from Co target at 10 I-LA for 1 h irradiation, and with the radionuclidic purity of >98% (EOS). The only radionuclidic impurity in the isolated Cu-61(2+) solution was identified to be Cu-60 at EOS but no radionuclidic impurity was observed after 50 hours. The solution of Cu-61-ATSM was prepared in >85% radiochemical yield with >95% radiochemical purity.
\nDo you want to read the rest of this article?
Request full-text

\nPractical production of 61Cu using natural Co target and its simple purification with a chelating resin for 61CU-ATSM. Available from: https://www.researchgate.net/publication/244745391_Practical_production_of_61Cu_using_natural_Co_target_and_its_simple_purification_with_a_chelating_resin_for_61CU-ATSM [accessed Mar 27, 2017].
書誌情報 Radiochimica Acta

巻 92, p. 209-214, 発行日 2004-03
ISSN
収録物識別子タイプ ISSN
収録物識別子 0033-8230
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:36:34.648284
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3