ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Comparison of carbon-ion passive and scanning irradiation for pancreatic cancer.

https://repo.qst.go.jp/records/47684
https://repo.qst.go.jp/records/47684
871414ff-892e-4418-ab57-b6b10fea18d1
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-03-25
タイトル
タイトル Comparison of carbon-ion passive and scanning irradiation for pancreatic cancer.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Shiomi, Miho

× Shiomi, Miho

WEKO 478458

Shiomi, Miho

Search repository
Mori, Shinichiro

× Mori, Shinichiro

WEKO 478459

Mori, Shinichiro

Search repository
Shinoto, Makoto

× Shinoto, Makoto

WEKO 478460

Shinoto, Makoto

Search repository
Nakayama, Yuko

× Nakayama, Yuko

WEKO 478461

Nakayama, Yuko

Search repository
Kamada, Tadashi

× Kamada, Tadashi

WEKO 478462

Kamada, Tadashi

Search repository
Yamada, Shigeru

× Yamada, Shigeru

WEKO 478463

Yamada, Shigeru

Search repository
塩見 美帆

× 塩見 美帆

WEKO 478464

en 塩見 美帆

Search repository
森 慎一郎

× 森 慎一郎

WEKO 478465

en 森 慎一郎

Search repository
篠藤 誠

× 篠藤 誠

WEKO 478466

en 篠藤 誠

Search repository
中山 優子

× 中山 優子

WEKO 478467

en 中山 優子

Search repository
鎌田 正

× 鎌田 正

WEKO 478468

en 鎌田 正

Search repository
山田 滋

× 山田 滋

WEKO 478469

en 山田 滋

Search repository
抄録
内容記述タイプ Abstract
内容記述 PURPOSE:
To compare carbon-ion beam dose distribution between passive and scanning radiation therapies for locally advanced pancreatic cancer.
MATERIALS AND METHODS:
Thirteen pancreatic cancer patients were included in this study. Four types of treatment planning with respiratory gating were calculated for each patient: a four-field box with passive irradiation (Plan 1), scanning irradiation (Plan 2), a three-field (150°, 180° and 210°) protocol with passive irradiation (Plan 3), and scanning irradiation (Plan 4). The irradiation plans each delivered 55.2Gy (RBE) to the planning target volume (PTV) and were compared with respect to doses to the PTV and organs at risk (OARs).
RESULTS:
Plan 3 exceeded the dose assessment metrics to the spinal cord. Scanning irradiation plans (Plan 2 and, particularly, Plan 4) offered significantly reduced dosage to the stomach and the duodenum compared with passive irradiation.
CONCLUSION:
Three-field oblique scanning irradiation for pancreatic cancer has the potential to reduce gastrointestinal exposure and influence of peristalsis on dose distribution.
書誌情報 Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology

巻 119, 号 2, p. 326-330, 発行日 2016-05
出版者
出版者 Elsevier Scientific Publishers
ISSN
収録物識別子タイプ ISSN
収録物識別子 0167-8140
PubMed番号
識別子タイプ PMID
関連識別子 27262617
DOI
識別子タイプ DOI
関連識別子 10.1016/j.radonc.2016.04.026
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:36:43.240985
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3