WEKO3
アイテム
Accelerated (99m)Tc-sestamibi clearance associated with mitochondrial dysfunction and regional left ventricular dysfunction in reperfused myocardium in patients with acute coronary syndrome.
https://repo.qst.go.jp/records/47666
https://repo.qst.go.jp/records/47666fd603ace-adac-4c03-bf18-ccf5f1e163aa
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-03-15 | |||||
タイトル | ||||||
タイトル | Accelerated (99m)Tc-sestamibi clearance associated with mitochondrial dysfunction and regional left ventricular dysfunction in reperfused myocardium in patients with acute coronary syndrome. | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Masuda, Atsuro
× Masuda, Atsuro× Yoshinaga, Keiichiro× Naya, Masanao× Manabe, Osamu× Yamada, Satoshi× Iwano, Hiroyuki× Okada, Tatsuya× Katoh, Chietsugu× Takeishi, Yasuchika× Tsutsui, Hiroyuki× Tamaki, Nagara× 吉永 恵一郎 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | BACKGROUND: Accelerated clearance of (99m)technetium-sestamibi (MIBI) has been observed after reperfusion therapy in patients with acute coronary syndrome (ACS), but the mechanisms have not been fully investigated. MIBI retention may depend on mitochondrial function. The clearance rate of (11)carbon-acetate reflects such mitochondrial functions as oxidative metabolism. The purpose of this study was to examine the mechanisms of accelerated MIBI clearance in ACS. We therefore compared it to oxidative metabolism estimated using (11)C-acetate positron emission tomography (PET). METHODS: Eighteen patients [mean age 69.2 ± 8.7 years, 10 males (56 %)] with reperfused ACS underwent MIBI single-photon emission computed tomography (SPECT), echocardiography, and (11)C-acetate PET within 3 weeks of the onset of ACS. MIBI images were obtained 30 min and 3 h after MIBI administration. Regional left ventricular (LV) function was evaluated by echocardiography. The measurement of oxidative metabolism was obtained through the mono-exponential fitting of the (11)C-acetate time-activity curve (k mono). RESULTS: Among 95 segments of reperfused myocardium, MIBI SPECT showed 64 normal segments (group N), 14 segments with accelerated MIBI clearance (group AC), and 17 segments with fixed defect (group F). Group AC showed lower k mono than group N (0.041 ± 0.009 vs 0.049 ± 0.010, p = 0.02). Group F showed lower k mono than group N (0.039 ± 0.012 vs 0.049 ± 0.010, p = 0.01). However, k mono was similar in group AC and group F (p = 0.99). CONCLUSIONS: Segments with accelerated MIBI clearance showed reduced oxidative metabolism in ACS. Loss of MIBI retention may be associated with mitochondrial dysfunction. |
|||||
書誌情報 |
EJNMMI Research 巻 6, 号 1, p. 41, 発行日 2016-12 |
|||||
出版者 | ||||||
出版者 | Springer Berlin | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 2191-219X | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 27169534 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1186/s13550-016-0196-5 |