Effective particle energies for stopping power calculation in radiotherapy treatment planning with protons and helium, carbon, and oxygen ions

https://repo.qst.go.jp/records/47636
https://repo.qst.go.jp/records/47636
26fe75e4-8320-4974-8aff-c5f5db4c1a1d
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-02-08
タイトル
タイトル Effective particle energies for stopping power calculation in radiotherapy treatment planning with protons and helium, carbon, and oxygen ions
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Inaniwa, Taku

× Inaniwa, Taku

WEKO 477722

Inaniwa, Taku

Search repository
Kanematsu, Nobuyuki

× Kanematsu, Nobuyuki

WEKO 477723

Kanematsu, Nobuyuki

Search repository
稲庭 拓

× 稲庭 拓

WEKO 477724

en 稲庭 拓

Search repository
兼松 伸幸

× 兼松 伸幸

WEKO 477725

en 兼松 伸幸

Search repository
抄録
内容記述タイプ Abstract
内容記述 The stopping power ratio (SPR) of body tissues relative to water depends on the particle energy. For simplicity, however, most analytical dose planning systems do not account for SPR variation with particle energy along the beam’s path, but rather assume a constant energy for SPR estimation. The range error due to this simplification could be indispensable depending on the particle species and the assumed energy. This error can be minimized by assuming a suitable energy referred to as an ‘effective energy’ in SPR estimation. To date, however, the effective energy has never been investigated for realistic patient geometries. We investigated the effective energies for proton, helium-, carbon-, and oxygen-ion radiotherapy using volumetric models of the reference male and female phantoms provided by the International Commission on Radiological Protection (ICRP). The range errors were estimated by comparing the particle ranges calculated when particle energy variations were and were not considered. The effective energies per nucleon for protons and helium, carbon, and oxygen ions were 70 MeV, 70 MeV, 131 MeV, and 156 MeV, respectively. Using the determined effective energies, the range errors were reduced to ⩽0.3 mm for respective particle species. For SPR estimation of multiple particle species, an effective energy of 100 MeV is recommended, with which the range error is ⩽0.5 mm for all particle species.
書誌情報 Physics in Medicine and Biology

巻 61, 号 20, p. N542-N550, 発行日 2016-10
出版者
出版者 IOP Publishing
ISSN
収録物識別子タイプ ISSN
収録物識別子 0031-9155
DOI
識別子タイプ DOI
関連識別子 10.1088/0031-9155/61/20/N542
関連サイト
識別子タイプ URI
関連識別子 http://iopscience.iop.org/article/10.1088/0031-9155/61/20/N542?fromSearchPage=true
関連名称 http://iopscience.iop.org/article/10.1088/0031-9155/61/20/N542?fromSearchPage=true
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:37:19.670036
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3