Optimization of the Timepix chip to measurement of radon, thoron and their progenies

https://repo.qst.go.jp/records/47606
https://repo.qst.go.jp/records/47606
fd3b33f5-29a0-47df-b6f2-f3b301f46b66
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-01-06
タイトル
タイトル Optimization of the Timepix chip to measurement of radon, thoron and their progenies
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 ミロソラフ, ヤニック

× ミロソラフ, ヤニック

WEKO 477186

ミロソラフ, ヤニック

Search repository
Ploc, Ondrej

× Ploc, Ondrej

WEKO 477187

Ploc, Ondrej

Search repository
Michael, Fiederle

× Michael, Fiederle

WEKO 477188

Michael, Fiederle

Search repository
Procz, Simon

× Procz, Simon

WEKO 477189

Procz, Simon

Search repository
Kavasi, Norbert

× Kavasi, Norbert

WEKO 477190

Kavasi, Norbert

Search repository
ミロソラフ ヤニック

× ミロソラフ ヤニック

WEKO 477191

en ミロソラフ ヤニック

Search repository
Kavasi Norbert

× Kavasi Norbert

WEKO 477192

en Kavasi Norbert

Search repository
抄録
内容記述タイプ Abstract
内容記述 Radon and thoron as well as their short-lived progenies are decay products of the radium and thorium series decays. They are the most important radionuclide elements with respect to public exposure. To utilize the semiconductor pixel radiation Timepix chip for the measurement of active and real-time alpha particles from radon, thoron and their progenies, it is necessary to check the registration and visualization of the chip.
An energy check for radon, thoron and their progenies, as well as for 241Am and210Po sources, was performed using the radon and thoron chambers at NIRS (National Institute of Radiological Sciences). The check found an energy resolution of 200 keV with a 14% efficiency as well as a linear dependency between the channel number (cluster volume) and the energy. The coefficient of determination r2 of 0.99 for the range of 5 to 9 MeV was calculated. In addition, an offset for specific Timepix configurations between pre-calibration for low energy from 6 to 60 keV, and the actual calibration for alpha particles with energies from 4000 to 9000 keV, was detected.
書誌情報 Applied Radiation and Isotopes

巻 107, p. 220-224, 発行日 2016-01
出版者
出版者 Elsevier
ISSN
収録物識別子タイプ ISSN
収録物識別子 0969-8043
DOI
識別子タイプ DOI
関連識別子 10.1016/j.apradiso.2015.10.023
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:37:41.103426
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3