  1. 原著論文

Treatment planning for the layer-stacking irradiation system for three-dimensional conformal heavy-ion radiotherapy

https://repo.qst.go.jp/records/47570
https://repo.qst.go.jp/records/47570
73d818bc-8426-4478-bf15-525c2a3da333
名前 / ファイル ライセンス アクション
774fabc3146fefefc6836c730a62439e.pdf Kanematsu2002.pdf (1.7 MB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2002-12-03
タイトル
タイトル Treatment planning for the layer-stacking irradiation system for three-dimensional conformal heavy-ion radiotherapy
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Kanematsu, Nobuyuki

× Kanematsu, Nobuyuki

WEKO 773959

Kanematsu, Nobuyuki

Search repository
Endo, Masahiro

× Endo, Masahiro

WEKO 773960

Endo, Masahiro

Search repository
Futami, Yasuyuki

× Futami, Yasuyuki

WEKO 773961

Futami, Yasuyuki

Search repository
Kanai, Tatsuaki

× Kanai, Tatsuaki

WEKO 773962

Kanai, Tatsuaki

Search repository
Asaskura, Hiroshi

× Asaskura, Hiroshi

WEKO 773963

Asaskura, Hiroshi

Search repository
Oka, Hiroyoshi

× Oka, Hiroyoshi

WEKO 773964

Oka, Hiroyoshi

Search repository
Yusa, Ken

× Yusa, Ken

WEKO 773965

Yusa, Ken

Search repository
Kanematsu, Nobuyuki

× Kanematsu, Nobuyuki

WEKO 773966

en Kanematsu, Nobuyuki

Search repository
Endo, Masahiro

× Endo, Masahiro

WEKO 773967

en Endo, Masahiro

Search repository
Futami, Yasuyuki

× Futami, Yasuyuki

WEKO 773968

en Futami, Yasuyuki

Search repository
Kanai, Tatsuaki

× Kanai, Tatsuaki

WEKO 773969

en Kanai, Tatsuaki

Search repository
Yusa, Ken

× Yusa, Ken

WEKO 773970

en Yusa, Ken

Search repository
抄録
内容記述タイプ Abstract
内容記述 We have upgraded a heavy-ion radiotherapy treatment-planning system to adapt for the layer-stacking irradiation method, which is to conform a variable spread-out Bragg peak to a target volume by means of dynamic control of the conventional beam-modifying devices. The biophysical model, the beam-setup logic, and the dose-calculation algorithm implemented for the layer-stacking method are described and the expected clinical usability is discussed. The layer-stacking method was integrated in perfect accordance with the ongoing conventional treatments so that the established protocols, which are the clinically optimized dose fractionation schemes, will still be valid. On the other hand, a simulation study indicated a substantial improvement of dose distribution with the layer-stacking method though the significance may depend on the size, shape, and location of the tumor. The completed treatment system will provide an option for improved conformal radiotherapy without interfering with the conventional method and we expect a gradual expansion of the clinical cases applicable to the layer-stacking method.
書誌情報 Medical Physics

巻 29, 号 12, p. 2823-2829, 発行日 2002-12
出版者
出版者 American Association of Physicists in Medicine
ISSN
収録物識別子タイプ ISSN
収録物識別子 0094-2405
PubMed番号
識別子タイプ PMID
関連識別子 12512716
DOI
識別子タイプ DOI
関連識別子 10.1118/1.1521938
関連サイト
識別子タイプ DOI
関連識別子 https://doi.org/10.1118/1.1521938
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:48:15.871343
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3