Evaluation of X-ray doses and their corresponding biological effects on experimental animals in cone-beam micro-CT scans (R-mCT2).

https://repo.qst.go.jp/records/47566
https://repo.qst.go.jp/records/47566
442e0c86-1c80-434b-85f7-9dd572824a3f
Item type 学術雑誌論文 / Journal Article(1)
公開日 2016-10-12
タイトル
タイトル Evaluation of X-ray doses and their corresponding biological effects on experimental animals in cone-beam micro-CT scans (R-mCT2).
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Miyahara, Nobuyuki

× Miyahara, Nobuyuki

WEKO 476789

Miyahara, Nobuyuki

Search repository
Kokubo, Toshiaki

× Kokubo, Toshiaki

WEKO 476790

Kokubo, Toshiaki

Search repository
Hara, Yukihiro

× Hara, Yukihiro

WEKO 476791

Hara, Yukihiro

Search repository
Yamada, Ayuta

× Yamada, Ayuta

WEKO 476792

Yamada, Ayuta

Search repository
Koike, Takafumi

× Koike, Takafumi

WEKO 476793

Koike, Takafumi

Search repository
Arai, Yoshinori

× Arai, Yoshinori

WEKO 476794

Arai, Yoshinori

Search repository
宮原 信幸

× 宮原 信幸

WEKO 476795

en 宮原 信幸

Search repository
小久保 年章

× 小久保 年章

WEKO 476796

en 小久保 年章

Search repository
抄録
内容記述タイプ Abstract
内容記述 Studies show that the radiation dose received during a micro-CT examination may have adverse effects on living subjects. However, the correlations between the biological effects and the radiation doses have never been thoroughly evaluated in the majority of cases. In this study, we evaluated the biological radiation effects of measured radiation doses in ICR mice using cone-beam micro-CT scans. Long-term in vivo whole-body micro-CT scans of ICR mice were performed for a duration of 4 weeks. Although a scanning frequency of three scans per week is higher than that necessary for conventional studies, this study represents particular cases where the subjects may undergo an extreme number of examinations. The average X-ray dose of a CT scan measures 16.19 mGy at the center of a phantom and 16.24 mGy at an offset position of 7.5 mm from the center of the phantom. The total average dose at the center of the phantom during the 4-week scanning period was 194.3 mGy. No significant radiation effects were observed in the weight gain curves, organ weights, blood analyses, litter sizes, reared offspring sizes, and the histopathologic results. Therefore, it is unlikely that the measured doses for the CT scans caused any radiation damage in the mice.
書誌情報 Radiological physics and technology

巻 9, 号 1, p. 60-68, 発行日 2016-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 1865-0333
PubMed番号
識別子タイプ PMID
関連識別子 26441335
DOI
識別子タイプ DOI
関連識別子 10.1007/s12194-015-0334-1
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:38:16.133293
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3