INTAKE RATIO OF I-131 TO CS-137 DERIVED FROM THYROID AND WHOLE-BODY DOSES TO FUKUSHIMA RESIDENTS

https://repo.qst.go.jp/records/47519
https://repo.qst.go.jp/records/47519
ff782fcd-8633-4085-affe-089edc52928f
Item type 学術雑誌論文 / Journal Article(1)
公開日 2016-08-30
タイトル
タイトル INTAKE RATIO OF I-131 TO CS-137 DERIVED FROM THYROID AND WHOLE-BODY DOSES TO FUKUSHIMA RESIDENTS
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 金, ウンジュ

× 金, ウンジュ

WEKO 476168

金, ウンジュ

Search repository
栗原, 治

× 栗原, 治

WEKO 476169

栗原, 治

Search repository
谷, 幸太郎

× 谷, 幸太郎

WEKO 476170

谷, 幸太郎

Search repository
大町, 康

× 大町, 康

WEKO 476171

大町, 康

Search repository
福津, 久美子

× 福津, 久美子

WEKO 476172

福津, 久美子

Search repository
酒井, 一夫

× 酒井, 一夫

WEKO 476173

酒井, 一夫

Search repository
明石, 真言

× 明石, 真言

WEKO 476174

明石, 真言

Search repository
金 ウンジュ

× 金 ウンジュ

WEKO 476175

en 金 ウンジュ

Search repository
栗原 治

× 栗原 治

WEKO 476176

en 栗原 治

Search repository
谷 幸太郎

× 谷 幸太郎

WEKO 476177

en 谷 幸太郎

Search repository
大町 康

× 大町 康

WEKO 476178

en 大町 康

Search repository
福津 久美子

× 福津 久美子

WEKO 476179

en 福津 久美子

Search repository
酒井 一夫

× 酒井 一夫

WEKO 476180

en 酒井 一夫

Search repository
明石 真言

× 明石 真言

WEKO 476181

en 明石 真言

Search repository
抄録
内容記述タイプ Abstract
内容記述 This study deals with the intake ratio of 131I to 137Cs that allows for the utilization of late whole-body measurements to reconstruct the internal thyroid doses to Fukushima residents. The ratio was derived from the thyroid dose distribution of children and the effective dose distribution of adults based on the assumption that various age-groups of persons inhaled the two nuclides at the same activity ratio and at around the same time, while taking into account age-dependent ventilation rates. The two dose distributions were obtained from residents of Iitate village and Kawamata town, located northwest of Fukushima Daiichi nuclear power plant (FDNPP). As a result, the intake ratios for the residents were 2~3, which was much smaller than the activity ratio observed in air sampling. A main reason for this discrepancy presumably lies in the relatively smaller thyroid uptake for iodine in the Japanese subjects than in the reference persons on whom the biokinetic model promulgated by International Commission on Radiological Protection (ICRP) is based. The actual intake ratio of the two nuclides is believed to have been higher south of the FDNPP; however, this would depend on which of three significant plume events dominantly contributed to the intake for individuals. Further studies are needed to clarify this issue as a part of the reconstruction of early internal doses related to the FDNPP accident.
書誌情報 Radiation Protection Dosimetry

巻 168, 号 3, p. 408-418, 発行日 2015-05
出版者
出版者 Oxford University Press.
ISSN
収録物識別子タイプ ISSN
収録物識別子 0144-8420
DOI
識別子タイプ DOI
関連識別子 10.1093/rpd/ncv344
関連サイト
識別子タイプ URI
関連識別子 http://rpd.oxfordjournals.org/content/early/2015/05/15/rpd.ncv344.abstract
関連名称 http://rpd.oxfordjournals.org/content/early/2015/05/15/rpd.ncv344.abstract
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:38:50.155455
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3