ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

ESTIMATION OF ORGAN DOSES AND EFFECTIVE DOSES IN IMAGE-GUIDED RESPIRATION-GATED RADIOTHERAPY

https://repo.qst.go.jp/records/47507
https://repo.qst.go.jp/records/47507
cdfa4115-c129-4f5e-aff1-99937d4b8273
Item type 学術雑誌論文 / Journal Article(1)
公開日 2016-08-25
タイトル
タイトル ESTIMATION OF ORGAN DOSES AND EFFECTIVE DOSES IN IMAGE-GUIDED RESPIRATION-GATED RADIOTHERAPY
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Nakao, Minoru

× Nakao, Minoru

WEKO 476025

Nakao, Minoru

Search repository
Obara, Satoshi

× Obara, Satoshi

WEKO 476026

Obara, Satoshi

Search repository
Nabatame, Kuniaki

× Nabatame, Kuniaki

WEKO 476027

Nabatame, Kuniaki

Search repository
Akahane, Keiichi

× Akahane, Keiichi

WEKO 476028

Akahane, Keiichi

Search repository
Sanada, Shigeru

× Sanada, Shigeru

WEKO 476029

Sanada, Shigeru

Search repository
Shirai, Toshiyuki

× Shirai, Toshiyuki

WEKO 476030

Shirai, Toshiyuki

Search repository
中尾 稔

× 中尾 稔

WEKO 476031

en 中尾 稔

Search repository
小原 哲

× 小原 哲

WEKO 476032

en 小原 哲

Search repository
青天目 州晶

× 青天目 州晶

WEKO 476033

en 青天目 州晶

Search repository
赤羽 恵一

× 赤羽 恵一

WEKO 476034

en 赤羽 恵一

Search repository
白井 敏之

× 白井 敏之

WEKO 476035

en 白井 敏之

Search repository
抄録
内容記述タイプ Abstract
内容記述 Dose conformity in thoracic and abdominal ion-beam radiotherapy is degraded by respiratory motion. To improve conformity, an image-guided respiration-gated system can be used in the treatment room. The purpose of this study was to estimate the organ doses and effective doses to patients from an image-guided respiration-gated system. Glass dosemeters were inserted into an adult anthropomorphic phantom and were attached to the surface on the phantom. The phantom was placed on the treatment couch, and the imaging dose from fluoroscopy was evaluated. In addition to the organ doses, the effective doses were also estimated according to the ICRP Publication 103. The irradiation time is over 3– 5 min per beam angle. When image acquisition conditions were assumed for thoracic treatment, the effective doses and maximal skin doses were 0.48– 0.79 mSv and 5.9– 9.9
mGy, respectively. The estimated doses can be the base data for considering radiological protection in the radiotherapy.
書誌情報 Radiation Protection Dosimetry

巻 168, 号 1, p. 83-91, 発行日 2015-04
出版者
出版者 Oxford University Press.
DOI
識別子タイプ DOI
関連識別子 10.1093/rpd/ncv015
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:38:58.915172
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3