ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Passive and electro-assisted delivery of hydrogel nanoparticles in solid tumors, visualized by optical and magnetic resonance imaging in vivo

https://repo.qst.go.jp/records/47463
https://repo.qst.go.jp/records/47463
0de05ee3-8337-4d0c-8c4e-3728b1749864
Item type 学術雑誌論文 / Journal Article(1)
公開日 2016-08-10
タイトル
タイトル Passive and electro-assisted delivery of hydrogel nanoparticles in solid tumors, visualized by optical and magnetic resonance imaging in vivo
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Bakalova-Zheleva, Rumiana

× Bakalova-Zheleva, Rumiana

WEKO 475482

Bakalova-Zheleva, Rumiana

Search repository
Pancheva, Nikolova-Lefterova Biliana

× Pancheva, Nikolova-Lefterova Biliana

WEKO 475483

Pancheva, Nikolova-Lefterova Biliana

Search repository
Murayama, Shuhei

× Murayama, Shuhei

WEKO 475484

Murayama, Shuhei

Search repository
Atanasova, Severina

× Atanasova, Severina

WEKO 475485

Atanasova, Severina

Search repository
Zhelev, Zhivko

× Zhelev, Zhivko

WEKO 475486

Zhelev, Zhivko

Search repository
Aoki, Ichio

× Aoki, Ichio

WEKO 475487

Aoki, Ichio

Search repository
Kato, Masaru

× Kato, Masaru

WEKO 475488

Kato, Masaru

Search repository
Tsoneva, Iana

× Tsoneva, Iana

WEKO 475489

Tsoneva, Iana

Search repository
Saga, Tsuneo

× Saga, Tsuneo

WEKO 475490

Saga, Tsuneo

Search repository
バカロバ ルミアナ

× バカロバ ルミアナ

WEKO 475491

en バカロバ ルミアナ

Search repository
ニコロヴァレフタロヴ� .咼螢▲福�

× ニコロヴァレフタロヴ� .咼螢▲福�

WEKO 475492

en ニコロヴァレフタロヴ� .咼螢▲福�

Search repository
村山 周平

× 村山 周平

WEKO 475493

en 村山 周平

Search repository
アタナソヴァ セヴァリナ

× アタナソヴァ セヴァリナ

WEKO 475494

en アタナソヴァ セヴァリナ

Search repository
Zhelev Zhivko

× Zhelev Zhivko

WEKO 475495

en Zhelev Zhivko

Search repository
青木 伊知男

× 青木 伊知男

WEKO 475496

en 青木 伊知男

Search repository
加藤 大

× 加藤 大

WEKO 475497

en 加藤 大

Search repository
佐賀 恒夫

× 佐賀 恒夫

WEKO 475498

en 佐賀 恒夫

Search repository
抄録
内容記述タイプ Abstract
内容記述 The present study describes a development of nanohydrogel, loaded with QD705 and manganese (QD705@Nanogel & QD705@Mn@Nanogel), and its passive and electro-assisted delivery in solid tumours, visualized by fluorescence imaging and magnetic resonance imaging (MRI) on colon-cancer grafted mice as a model.
QD705@Nanogel was delivered passively predominantly into the tumor, which was visualized in vivo and ex vivo using fluorescent imaging. The fluorescence intensity increased gradually within 30 min after injection, reached a plateau between 30 min and 2 hours, and decreased gradually to the baseline within 24 hours. The fluorescence intensity in the tumor area was about 2.5 times higher than the background fluorescence. A very weak fluorescent signal was detected in the liver area, but not in the areas of kidneys or bladder. This result was in contrast with our previous study, indicating that FITC@Mn@Nanogel did not enter into the tumor and was detected rapidly in the kidney and bladder after i.v. injection [J. Mater. Chem. B 2013, 1, 4932-4938]. We found that the embedding of a hard material (as QD) in nanohydrogel changes the physical properties of the soft material (decreases the size and negative charge and changes the shape) and alters its pharmacodynamics.
Electroporation facilitated the delivery of the nanohydrogel in the tumor tissue, visualized by fluorescent imaging and MRI. Strong signal intensity was recorded in the tumor area shortly after the combined treatment (QD@Mn@Nanogel + electroporation) and it was observed even 48 hours after the electroporation. The data demonstrate more effective penetration of the nanoparticles in the tumor due to the increased permeability of blood vessels at the electroporated area. There was no rupture of blood vessels after electroporation and there were no artifacts in the images due to a bleeding.
書誌情報 Analytical and Bioanalytical Chemistry

巻 408, 号 3, p. 905-914, 発行日 2015-12
出版者
出版者 Springer-Verlag
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:39:32.900017
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3