WEKO3
アイテム
Accurate quantitative measurements of brachial artery cross-sectional area and volume elastic modulus using automated oscillometric methods comparison with ultrasound
https://repo.qst.go.jp/records/47447
https://repo.qst.go.jp/records/4744708157418-664d-49c4-b552-218b1ed061dd
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2016-08-10 | |||||
タイトル | ||||||
タイトル | Accurate quantitative measurements of brachial artery cross-sectional area and volume elastic modulus using automated oscillometric methods comparison with ultrasound | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Tomiyama, Yuuki
× Tomiyama, Yuuki× Keiichiro, Yoshinaga× Fujii, Satoshi× Ochi, Noriki× Inoue, Mamiko× Nishida, Mutumi× Aziki, Kumi× Horie, Tatsunori× Katoh, Chietsugu× Tamaki, Nagara× 吉永 恵一郎 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Increasing vascular diameter and attenuated vascular elasticity may be a reliable marker for atherosclerotic risk assessment. However, previous measurements have been complex, operator dependent, or invasive. Recently, we developed a new automated oscillometric method to measure a brachial artery’s estimated area (eA) and volume elastic modulus (VE). The aim of this study was to investigate the reliability of new automated oscillometric measurement of eA and VE. Rest eA and VE were measured using the recently developed automated detector with an oscillometric method. eA was estimated using pressure-volume curves and VE was defined as follows [VE =Δ Pressure/ (100 × Δ Area/ Area) mmHg/%]. Sixteen volunteers (age 35.2 ± 13.1) underwent the oscillometric measurements and brachial ultrasound at rest and under nitroglycerin (NTG) administration. Oscillometric measurement was performed twice on different days. The rest eA correlated with brachial diameter measured by ultrasound (r = 0.75, P < 0.001). Rest eA and VE measurement showed good reproducibility (eA: ICC = 0.88, VE: ICC = 0 .78). Under NTG stress, eA was significantly increased (12.3±3.0 vs. 17.1±4.6 mm2, P < 0.001), which was similar to the case with ultrasound evaluation (4.46±0.72 vs. 4.73±0.75 mm, P < 0.001. VE was also decreased (0.81±0.16 vs. 0.65±0.11 mmHg/%, P < 0.001) after NTG. Cross-sectional vascular area calculated using this automated oscillometric measurement correlated with ultrasound measurement and showed good reproducibility. Therefore, this was a reliable approach and this modality may have practical application to automatically assess conduit artery diameter and elasticity in clinical or epidemiological settings. | |||||
書誌情報 |
Hypertension Research 巻 38, 号 7, p. 478-484, 発行日 2015-02 |
|||||
出版者 | ||||||
出版者 | Nature publishing Group | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0916-9636 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 25693851 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1038/hr.2015.6 |