ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

COMPARATIVE STUDY OF VARIOUS TECHNIQUES FOR ENVIRONMENTAL RADON, THORON AND PROGENY MEASUREMENTS

https://repo.qst.go.jp/records/47374
https://repo.qst.go.jp/records/47374
dfd59059-2bb7-411c-911b-6bcd7476426a
Item type 学術雑誌論文 / Journal Article(1)
公開日 2016-01-18
タイトル
タイトル COMPARATIVE STUDY OF VARIOUS TECHNIQUES FOR ENVIRONMENTAL RADON, THORON AND PROGENY MEASUREMENTS
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Ramola, R.C.

× Ramola, R.C.

WEKO 474189

Ramola, R.C.

Search repository
Prasad, M.

× Prasad, M.

WEKO 474190

Prasad, M.

Search repository
Rawat, M.

× Rawat, M.

WEKO 474191

Rawat, M.

Search repository
Dangwal, A.

× Dangwal, A.

WEKO 474192

Dangwal, A.

Search repository
Gusain, G.S.

× Gusain, G.S.

WEKO 474193

Gusain, G.S.

Search repository
Mishra, R.

× Mishra, R.

WEKO 474194

Mishra, R.

Search repository
Sahoo, S.K.

× Sahoo, S.K.

WEKO 474195

Sahoo, S.K.

Search repository
S.Tokonami

× S.Tokonami

WEKO 474196

S.Tokonami

Search repository
サフー サラタ クマール

× サフー サラタ クマール

WEKO 474197

en サフー サラタ クマール

Search repository
抄録
内容記述タイプ Abstract
内容記述 Long-term average concentrations of radon, thoron and progeny were measured in normal and high background radiation areas in India using different techniques. Radon, thoron and progeny concentrations were measured using Raduet, Pin-Hole dosimeter, deposition-based CR-39 and deposition-based direct radon/thoron progeny sensor (DRPS/DTPS) detector system. All these techniques were used at a same time inside an individual dwelling. Radon concentration was recorded higher than thoron concen- tration in Garhwal Homes (NBRA) while thoron concentration was found relatively higher in the houses of Chhatarpur area (HBRA) in Odisha, India. The values measured with the CR-39 detector-based technique were found comparable with the values measured with the LR-115 detector-based technique. The comparisons of results using various techniques and their usefulness in radiation measurements are discussed in detail.
書誌情報 Radiation Protection Dosimetry

巻 167, 号 1-3, p. 22-28, 発行日 2015-11
出版者
出版者 Oxford University Press
ISSN
収録物識別子タイプ ISSN
収録物識別子 0144-8420
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:40:36.905468
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3