ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

In vivo radiobiological assessment of the new clinical varbon ion beams at CNAO

https://repo.qst.go.jp/records/47372
https://repo.qst.go.jp/records/47372
b464c164-6b25-4f79-8f95-e4f7eebf51b4
Item type 学術雑誌論文 / Journal Article(1)
公開日 2016-01-18
タイトル
タイトル In vivo radiobiological assessment of the new clinical varbon ion beams at CNAO
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 FACOETTI, Angelica

× FACOETTI, Angelica

WEKO 474166

FACOETTI, Angelica

Search repository
Barbara, Vischioni

× Barbara, Vischioni

WEKO 474167

Barbara, Vischioni

Search repository
Ciocca, M.

× Ciocca, M.

WEKO 474168

Ciocca, M.

Search repository
Ferrarini, M.

× Ferrarini, M.

WEKO 474169

Ferrarini, M.

Search repository
古澤, 佳也

× 古澤, 佳也

WEKO 474170

古澤, 佳也

Search repository
Mairani, A.

× Mairani, A.

WEKO 474171

Mairani, A.

Search repository
松本, 孔貴

× 松本, 孔貴

WEKO 474172

松本, 孔貴

Search repository
Mirandola, A.

× Mirandola, A.

WEKO 474173

Mirandola, A.

Search repository
Molinelli, S.

× Molinelli, S.

WEKO 474174

Molinelli, S.

Search repository
鵜澤, 玲子

× 鵜澤, 玲子

WEKO 474175

鵜澤, 玲子

Search repository
G., Vilches Freixas

× G., Vilches Freixas

WEKO 474176

G., Vilches Freixas

Search repository
R.Orecchia

× R.Orecchia

WEKO 474177

R.Orecchia

Search repository
Vischioni Barbara

× Vischioni Barbara

WEKO 474178

en Vischioni Barbara

Search repository
古澤 佳也

× 古澤 佳也

WEKO 474179

en 古澤 佳也

Search repository
松本 孔貴

× 松本 孔貴

WEKO 474180

en 松本 孔貴

Search repository
鵜澤 玲子

× 鵜澤 玲子

WEKO 474181

en 鵜澤 玲子

Search repository
抄録
内容記述タイプ Abstract
内容記述 In this article, the in vivo study performed to evaluate the uniformity of biological doses within an hypothetical target volume and calculate the values of relative biological effectiveness (RBE) at different depths in the spread-out Bragg peak (SOBP) of the new CNAO (National Centre for Oncological Hadrontherapy) carbon beams is presented, in the framework of a typical radiobiological beam calibration procedure. The RBE values (relative to 60Co g rays) of the CNAO active scanning carbon ion beams were determined using jejunal crypt regeneration in mice as biological system at the entrance, centre and distal end of a 6-cm SOBP. The RBE values calculated from the iso-effective doses to reduce crypt survival per circumference to 10, ranged from 1.52 at the middle of the SOBP to 1.75 at the distal position and are in agreement with those previously reported from other carbon ion facilities. In conclusion, this first set of in vivo experiments shows that the CNAO carbon beam is radiobiologically comparable with the NIRS (National Institute of Radiological Sciences, Chiba, Japan) and GSI (Helmholtzzentrum fu¨r Schwerionenforschung, Darmstadt, Germany) ones.
書誌情報 Radiation Protection Dosimetry

巻 166, 号 1-4, p. 379-382, 発行日 2015-09
出版者
出版者 Oxford University Press
ISSN
収録物識別子タイプ ISSN
収録物識別子 0144-8420
PubMed番号
識別子タイプ PMID
関連識別子 25877541
DOI
識別子タイプ DOI
関連識別子 10.1093/rpd/ncv145
関連サイト
識別子タイプ URI
関連識別子 http://rpd.oxfordjournals.org/content/early/2015/04/15/rpd.ncv145
関連名称 http://rpd.oxfordjournals.org/content/early/2015/04/15/rpd.ncv145
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:40:38.426036
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3