A dose calculation algorithm with correction for proton-nucleus interactions in non-water materials for proton radiotherapy treatment planning

https://repo.qst.go.jp/records/47365
https://repo.qst.go.jp/records/47365
23800709-a6b8-46d6-8b8f-9320b602f2ef
Item type 学術雑誌論文 / Journal Article(1)
公開日 2016-01-18
タイトル
タイトル A dose calculation algorithm with correction for proton-nucleus interactions in non-water materials for proton radiotherapy treatment planning
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Inaniwa, Taku

× Inaniwa, Taku

WEKO 474096

Inaniwa, Taku

Search repository
Kanematsu, Nobuyuki

× Kanematsu, Nobuyuki

WEKO 474097

Kanematsu, Nobuyuki

Search repository
Sato, Shinji

× Sato, Shinji

WEKO 474098

Sato, Shinji

Search repository
Kohno, R.

× Kohno, R.

WEKO 474099

Kohno, R.

Search repository
稲庭 拓

× 稲庭 拓

WEKO 474100

en 稲庭 拓

Search repository
兼松 伸幸

× 兼松 伸幸

WEKO 474101

en 兼松 伸幸

Search repository
佐藤 眞二

× 佐藤 眞二

WEKO 474102

en 佐藤 眞二

Search repository
抄録
内容記述タイプ Abstract
内容記述 In treatment planning for proton radiotherapy, the dose measured in water is applied to the patient dose calculation with density scaling by stopping power ratio ps. Since the body tissues are chemically different from water, this approximation may cause dose calculation errors, especially due to differences in nuclear interactions. We proposed and validated an algorithm for correcting these errors. The dose in water is decomposed into three constituents according to the physical interactions of protons in water: the dose from primary protons continuously slowing down by electromagnetic interactions, the dose from protons scattered by elastic and/or inelastic interactions, and the dose resulting from nonelastic interactions. The proportions of the three dose constituents differ between body tissues and water. We determine correction factors for the proportion of dose constituents with Monte Carlo simulations in various standard body tissues, and formulated them as functions of their ps for patient dose calculation. The influence of nuclear interactions on dose was assessed by comparing the Monte Carlo simulated dose and the uncorrected dose in common phantom materials. The influence around the Bragg peak amounted to  −6% for polytetrafluoroethylene and 0.3% for polyethylene. The validity of the correction method was confirmed by comparing the simulated and corrected doses in the materials. The deviation was below 0.8% for all materials. The accuracy of the correction factors derived with Monte Carlo simulations was separately verified through irradiation experiments with a 235 MeV proton beam using common phantom materials. The corrected doses agreed with the measurements within 0.4% for all materials except graphite. The influence on tumor dose was assessed in a prostate case. The dose reduction in the tumor was below 0.5%. Our results verify that this algorithm is practical and accurate for proton radiotherapy treatment planning, and will also be useful in rapidly determining fluence correction factors for non-water phantom dosimetry.
書誌情報 Physics in Medicine and Biology

巻 61, 号 1, p. 67-89, 発行日 2015-11
出版者
出版者 IOP Publishing
ISSN
収録物識別子タイプ ISSN
収録物識別子 0031-9155
DOI
識別子タイプ DOI
関連識別子 doi:10.1088/issn.0031-9155/61/1/67
関連サイト
識別子タイプ DOI
関連識別子 http://dx.doi.org/10.1088/0031-9155/61/1/67
関連名称 http://dx.doi.org/10.1088/0031-9155/61/1/67
戻る
0
views
See details
Views