ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Construction of a cytogenetic dose-response curve for low-dose range gamma-irradiation in human peripheral blood lymphocytes using three-color FISH

https://repo.qst.go.jp/records/47356
https://repo.qst.go.jp/records/47356
b27e773e-529d-4e2e-a84c-b52345cb7eec
Item type 学術雑誌論文 / Journal Article(1)
公開日 2016-01-18
タイトル
タイトル Construction of a cytogenetic dose-response curve for low-dose range gamma-irradiation in human peripheral blood lymphocytes using three-color FISH
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 數藤, 由美子

× 數藤, 由美子

WEKO 473963

數藤, 由美子

Search repository
穐山, 美穂

× 穐山, 美穂

WEKO 473964

穐山, 美穂

Search repository
野田, 隆司

× 野田, 隆司

WEKO 473965

野田, 隆司

Search repository
平井, 百樹

× 平井, 百樹

WEKO 473966

平井, 百樹

Search repository
數藤 由美子

× 數藤 由美子

WEKO 473967

en 數藤 由美子

Search repository
穐山 美穂

× 穐山 美穂

WEKO 473968

en 穐山 美穂

Search repository
野田 隆司

× 野田 隆司

WEKO 473969

en 野田 隆司

Search repository
平井 百樹

× 平井 百樹

WEKO 473970

en 平井 百樹

Search repository
抄録
内容記述タイプ Abstract
内容記述 In order to estimate biological doses after low-dose ionizing radiation exposure, fluorescence in situ hybridization (FISH) using three differentially colored chromosome painting probes was employed to detect exchange-type chromosome aberrations. A reference dose response curve was constructed using blood samples from a female donor whose lymphocytes consistently exhibited a low frequency of cells at the second mitosis under routine culture conditions. Aberration yields were studied for a total of about 155 thousand metaphases obtained from seven dose-points of gamma irradiations (0, 50, 100, 150, 200, 250 and 300 mGy). In situ hybridization was performed using commercially available painting probes for chromosomes 1, 2 and 4. With the aid of an automated image-capturing method, exchange-type aberrations involving painted chromosomes were detected with considerable accuracy and speed. The results on the exchange-type aberrations (dicentrics plus translocations) at the seven dose-points showed a good fit to the linear-quadratic model (y = 0.0023 + 0.0015x + 0.0819x2, P = 0.83). A blind test proved the reproducibility of the reference dose-response relationship. In the control experiments using blood samples from another donor, the estimated doses calculated on the basis of the present reference curve were proved to be in good agreement with the actual physical doses applied. The present dose-response curve may serve as a means to assess the individual differences in cytogenetical radio-sensitivities.
書誌情報 Mutation Research - Genetic Toxicology and Environmental Mutagenesis

巻 794, p. 32-38, 発行日 2015-12
出版者
出版者 Elsevier
ISSN
収録物識別子タイプ ISSN
収録物識別子 1383-5718
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:40:49.662304
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3