  1. 原著論文

A Bayesian hierarchical method to account for random effects in cytogenetic dosimetry based on calibration curves

https://repo.qst.go.jp/records/47321
https://repo.qst.go.jp/records/47321
73f98837-d647-486c-9a06-50a57d1fdf1d
Item type 学術雑誌論文 / Journal Article(1)
公開日 2015-11-04
タイトル
タイトル A Bayesian hierarchical method to account for random effects in cytogenetic dosimetry based on calibration curves
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Mano, Shuhei

× Mano, Shuhei

WEKO 473380

Mano, Shuhei

Search repository
數藤, 由美子

× 數藤, 由美子

WEKO 473381

數藤, 由美子

Search repository
數藤 由美子

× 數藤 由美子

WEKO 473382

en 數藤 由美子

Search repository
抄録
内容記述タイプ Abstract
内容記述 The dicentric chromosome assay (DCA) is one of the most sensitive and reliable
methods of inferring doses of radiation exposure in patients. In DCA, one calibration curve is prepared in advance by in vitro irradiation to blood samples from one or sometimes multiple healthy donors in considering possible inter-individual variability. Although the standard method has been demonstrated to be quite accurate for actual dose estimates, it cannot account for random effects, which come from such as the blood donor used to prepare the calibration curve, the radiation-exposed patient, and the examiners. To date, it is unknown how these random effects impact on the standard method of dose estimation. We propose a novel Bayesian hierarchical method that incorporates random effects into the dose estimation. To demonstrate dose estimation by the proposed method and to assess the impact of inter-individual variability in samples from multiple donors on the estimation, peripheral blood samples from 13 occupationally non-exposed, non-smoking, healthy individuals were collected and irradiated with gamma-rays. The results clearly showed significant inter-individual variability and the standard method using a sample from a single donor gave anticonservative confidence interval of the irradiated dose. In contrast, the Bayesian credible interval for irradiated dose calculated by the proposed method using samples from multiple donors properly covered the actual doses. Although the classical confidence interval of calibration curve with accounting inter-individual variability in samples from multiple donors was roughly coincident with the Bayesian credible interval, the proposed method has better reasoning and potential for extensions.
書誌情報 Radiation and Environmental Biophysics

巻 53, 号 4, p. 775-780, 発行日 2014-08
出版者
出版者 Springer
ISSN
収録物識別子タイプ ISSN
収録物識別子 0301-634X
関連サイト
識別子タイプ URI
関連識別子 http://link.springer.com/article/10.1007/s00411-014-0563-4
関連名称 http://link.springer.com/article/10.1007/s00411-014-0563-4
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:41:10.827887
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3