ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Calibration of modified Liulin detector for cosmic radiation measurements on-board aircraft

https://repo.qst.go.jp/records/47299
https://repo.qst.go.jp/records/47299
a7407653-956f-4a5d-a701-6bd510853d26
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2015-09-15
タイトル
タイトル Calibration of modified Liulin detector for cosmic radiation measurements on-board aircraft
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 kyselova, D.

× kyselova, D.

WEKO 473059

kyselova, D.

Search repository
Ambrozova, I.

× Ambrozova, I.

WEKO 473060

Ambrozova, I.

Search repository
Krist, P.

× Krist, P.

WEKO 473061

Krist, P.

Search repository
Uchihori, Y.

× Uchihori, Y.

WEKO 473062

Uchihori, Y.

Search repository
Kitamura, H.

× Kitamura, H.

WEKO 473063

Kitamura, H.

Search repository
Ploc, O.

× Ploc, O.

WEKO 473064

Ploc, O.

Search repository
al., et

× al., et

WEKO 473065

al., et

Search repository
イバ アンブロツォヴァ

× イバ アンブロツォヴァ

WEKO 473066

en イバ アンブロツォヴァ

Search repository
内堀 幸夫

× 内堀 幸夫

WEKO 473067

en 内堀 幸夫

Search repository
北村 尚

× 北村 尚

WEKO 473068

en 北村 尚

Search repository
Ploc Ondrej

× Ploc Ondrej

WEKO 473069

en Ploc Ondrej

Search repository
抄録
内容記述タイプ Abstract
内容記述 The annual effective doses of aircrew members often exceed the limit of 1 mSv for the public due to the increased level of cosmic radiation at the flight altitudes, and thus, it is recommended to monitor them. Aircrew dosimetry is usually performed using special computer programs mostly based on results of Monte Carlo simulations. Contemporary, detectors are used mostly for validation of these computer codes, verification of effective dose calculations and for research purposes. One of such detectors is active silicon semiconductor deposited energy spectrometer Liulin. Output quantities of measurement with the Liulin detector are the absorbed dose in silicon D and the ambient dose equivalent H*(10); to determine it, two calibrations are necessary. The purpose of this work was to develop a calibration methodology that can be used to convert signal from the detector to D independently on calibration performed at Heavy Ion Medical Accelerator facility in Chiba, Japan.
書誌情報 Radiation Protection Dosimetry

巻 164, 号 4, p. 489-492, 発行日 2015-06
出版者
出版者 Oxford University Press
ISSN
収録物識別子タイプ ISSN
収録物識別子 0144-8420
DOI
識別子タイプ DOI
関連識別子 10.1093/rpd/ncv332
関連サイト
識別子タイプ URI
関連識別子 http://rpd.oxfordjournals.org/content/164/4/489.full
関連名称 http://rpd.oxfordjournals.org/content/164/4/489.full
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:41:26.679366
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3